Inspections for the day of: Monday, January 26, 2009.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC06-01232 General Inspection1/26/20091/26/20091/26/2009 4:16:55 PMPPASS
looked ok, no sign up, essentially done, could final, job taken over by new contractor, rest of permits expired from original contractor
ESC08-00700 General Inspection1/26/20091/26/20091/26/2009 4:10:00 PMPCANC
didn't need to go to site, will check at ri
ELE08-03237 Final1/26/20091/26/20091/26/2009 4:08:58 PMPPASS
Mike Phone #: ###-####--please call for key information called contractor, ok to final, no esc this project
ELE08-03254 Conference1/26/20091/26/20091/26/2009 3:24:49 PMPDONE
darin Note: just a telephone will be fine Phone #: ###-#### talked about conduit in crawl space for commercial building and also mc cable, said conduit supported on grade with supports is ok
ESC08-00847 General Inspection1/26/20091/26/20091/26/2009 2:54:32 PMPPART
didn't see sign, parking problem for site, need to park in neighbors driveway, will re-check when go back for corrections
ELE08-02584 Electrical Rough-In1/26/20091/26/20091/26/2009 2:16:51 PMPFAIL
robert Phone #: ###-#### met owner, corrections: BCC shall provide all make-up , NEC 210.52 shall provide outlet spacing entering kitchen, no esc this project
ELE08-01922 Final1/26/20091/26/20091/26/2009 1:41:34 PMPPASS
Jean Phone #: ###-#### corrections made, ok to final
ELE09-00015 Electrical Rough-In1/26/20091/26/20091/26/2009 12:32:05 PMPFAIL
darrin Phone #: ###-#### called left message, left correction notice, NEC 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 210.52(H) hallway over 10' in length shall have receptacle outlet, BCC all boxes shall be installed and made-up- baths and room adjoining existing house
ESC06-01299 General Inspection1/26/20091/26/20091/26/2009 9:24:33 AMAPASS
looked ok
ELE07-03307 Electrical Rough-In1/22/20091/26/20091/26/2009 8:30:36 AMAPASS
Contact Neil Ramsey. Rough-in inspection 1st floor ceiling. Also, 6th and 7th floor ceiling inspections. Phone #: ###-#### Internet Inspection Request from: Shelli Daylong 1st floor west soffit and 7th floor ceiling ok to cover
ELE09-00125 Electrical Rough-In1/23/20091/26/20091/26/2009 12:00:00 AMACANC
Please provide wall cover inspection. Phone #: ###-#### Internet Inspection Request from: Spencer Mclean