ELE09-02059
| ELE-Aging Inspection | 1/26/2010 | 1/26/2010 | 1/28/2010 9:51:50 AM | | DONE |
|
|
looked at sign, ok to final
|
ELE08-02826
| ELE-Aging Inspection | 1/26/2010 | 1/26/2010 | 1/27/2010 3:35:48 PM | | DONE |
|
|
no activity, see doc expire
|
ELE08-02790
| ELE-Aging Inspection | 1/26/2010 | 1/26/2010 | 1/27/2010 3:32:25 PM | | DONE |
|
|
no activity, see doc expire
|
ELE10-00151
| Temporary Service | 1/26/2010 | 1/26/2010 | 1/27/2010 8:11:04 AM | P | FAIL |
|
|
Dino Phone #: ###-#### called, left correction notice, NEC 250.24 shall connect grounded conductor to grounding electrode conductor via main bonding jumper
|
ELE09-02159
| Electrical Rough-In | 1/22/2010 | 1/26/2010 | 1/26/2010 4:01:15 PM | P | PASS |
|
|
Please final this permit when you are finished. Owner will give you the tour. Thanks!!! Dan. Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ri ok, no esc this project
|
ELE09-02159
| Final | 1/26/2010 | 1/26/2010 | 1/26/2010 4:00:19 PM | P | PASS |
|
|
Please final this permit when you are finished. Owner will give you the tour. Thanks!!! Dan. Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ok to final, no esc this project
|
ESC09-00801
| General Inspection | 1/26/2010 | 1/26/2010 | 1/26/2010 3:45:15 PM | P | PASS |
|
|
looked ok
|
ESC09-00203
| General Inspection | 1/26/2010 | 1/26/2010 | 1/26/2010 3:42:45 PM | P | PASS |
|
|
looked ok
|
ELE10-00103
| Electrical Rough-In | 1/26/2010 | 1/26/2010 | 1/26/2010 3:15:05 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Steve McCloy walls and u/g ok to cover, no esc this project
|
ELE07-02961
| Final | 1/26/2010 | 1/26/2010 | 1/26/2010 2:08:03 PM | P | PASS |
|
|
John Phone #: ###-#### ok to final, owner moved in, checked available receptacles only, no esc this project
|
ELE10-00109
| Electrical Rough-In | 1/26/2010 | 1/26/2010 | 1/26/2010 1:08:39 PM | P | PASS |
|
|
underground Phone #: ###-#### Internet Inspection Request from: Daniel Schaffeld ok to cover u/g, reviewed service disconnects and grounding
|
ELE10-00130
| Rough-In Permanent Service | 1/26/2010 | 1/26/2010 | 1/26/2010 12:30:15 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Joe Thomas corrections made, ric ok, p/s u/g n ok, no esc this project
|
ELE09-01997
| Electrical Rough-In | 1/25/2010 | 1/26/2010 | 1/26/2010 10:07:39 AM | A | PART |
|
|
Gene is on-site - ###-####. Middle 10 units and corridor on East side only. Thanks Jack!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson ric ok anop
|
ELE10-00145
| Temporary Service | 1/25/2010 | 1/26/2010 | 1/26/2010 9:04:40 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Emmet Bushman called, left correction notice- see list for ele10-00144, fee due
|
ELE10-00144
| Temporary Service | 1/25/2010 | 1/26/2010 | 1/26/2010 9:02:21 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Emmet Bushman called, left correction notice, same comments ele10-00145, NEC 406.8(B) 15 and 20a non-locking receptacles shall be listed weather resistant type, 312.5 conductors entering enclosures shall be protected from abrasion, 110.12(B) enclosures and equipment shall not be broken or contaminated by foreign materials, 250.53(G) upper end of electrode shall be flush with or below ground, BCC job id sticker shall be posted, address shall be posted, fee due
|
ELE09-02099
| Permanent Service | 1/25/2010 | 1/26/2010 | 1/26/2010 8:23:18 AM | A | PASS |
|
|
Meter base was changed since service was approved so need new inspection and sticker for IPCO connect. Phone #: ###-#### Internet Inspection Request from: Scott Abbott new meter base, p/s o/h n ok, no esc this project
|