Inspections for the day of: Friday, January 27, 2006.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD05-03379 BLD-Foundation1/27/20061/27/20061/27/2006 3:00:54 PMPPART
early as possible//rick; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. Being placed at same time as footing.
BLD05-03379 BLD-Footing1/27/20061/27/20061/27/2006 3:00:16 PMPPART
early as possible//rick; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa Forms in place. setback ok. reinforcement not yet installed as per plan. Called Rick and left message regarding reinforcement.
BLD05-03005 BLD-Energy code compliance1/27/20061/27/20061/27/2006 2:31:00 PMPPASS
John; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. All framing repairs ok. ok to cover.
BLD05-03395 BLD-Energy code compliance1/26/20061/27/20061/27/2006 2:06:04 PMPPASS
Ben; Phone #: ###-#### Internet Inspection Request from: ben davis

1-26-06/Rescheduled from 1/30 to 1/27 PM per Ben
BLD05-01119 BLD-Final1/26/20061/27/20061/27/2006 1:58:35 PMPPASS
Paul; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. ok for perm occ.
BLD05-02621 BLD-Framing/Rough-in1/26/20061/27/20061/27/2006 10:36:08 AMAFAIL
Chris -- call 1st before insp; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Complete nailing of all simpson hangars. Provide blocking between attic trusses at bonus room. Justify 2x8 header in leiu of the 2 9.5 inch ml as noted on plans at opening to master bedroom.
BLD05-02284 BLD-Framing/Rough-in1/26/20061/27/20061/27/2006 10:15:17 AMAPART
andy --party wall; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie. 1hr seperation wall, inner layer. Attached per GAWP 3514 as noted on plans.
BLD05-02283 BLD-Framing/Rough-in1/26/20061/27/20061/27/2006 10:14:07 AMAPART
andy --party wall; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie. 1hr seperation wall, inner layer. Attached per GAWP 3514 as noted on plans.
BLD05-01833 BLD-Framing/Rough-in1/26/20061/27/20061/27/2006 10:12:39 AMAPART
Scott; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Trusses repaired as to not penetrate the 1hr wall membrane. Reveiwed truss engineering for repaires on cut trusses, girder truss repaired incorrectly. Needs to complete lateral bracing, remove remaining wood penetrations from 1hr wall. All non rated boxes were removed and replaced with rated 1hr boxes. ok to insulate. c/n posted.
BLD05-01835 BLD-Framing/Rough-in1/26/20061/27/20061/27/2006 10:04:40 AMAPART
Scott; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Wood trusses cut back so as to not penetrate 1hr membrane. Reveiwed truss engineering for repairs on cut trusses. Girder truss repaired incorrectly. Needs to complete lateral bracing and remove remaining wood penetrations from 1hr wall. Also noted that non rated boxes have been removed and replaced with rated 1hr boxes. ok to insulate. c/n posted.