Inspections for the day of: Tuesday, January 27, 2009.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-00275 ELE-Aging Inspection1/27/20091/27/20091/27/2009 4:00:32 PM DONE
talked with contractor, he will check on status of project and call for inspection when job ready, no esc this project
ELE09-00105 Electrical Rough-In1/27/20091/27/20091/27/2009 3:56:53 PMPPASS
joe Phone #: ###-#### corrections made ric ok, kitchen and dining room only, no esc this project
ESC08-00998 General Inspection1/27/20091/27/20091/27/2009 3:15:03 PMPPART
yellow sign inside, all excavation under concrete blankets, looked ok for track-out, but couldn't see all, open trench, snow covered perimeter
ELE08-01818 ELE-Aging Inspection1/27/20091/27/20091/27/2009 2:25:11 PM DONE
see final, no esc this project
ELE08-01818 Final1/27/20091/27/20091/27/2009 2:25:01 PMPPASS
ok to final, no esc this project
ELE08-01817 ELE-Aging Inspection1/27/20091/27/20091/27/2009 1:58:15 PM DONE
see final, no esc this project
ELE08-01817 Final1/27/20091/27/20091/27/2009 1:57:48 PMPPASS
ok to final, no esc this oroject
ELE09-00057 Final1/27/20091/27/20091/27/2009 1:31:09 PMPPASS
Added smoke detector and outlet in new upstairs bedroom. Call if you have any questions. Thanks, Eric ###-#### Phone #: ###-#### Internet Inspection Request from: Eric Schroeder ok to final, no esc this project
ELE09-00135 Final1/26/20091/27/20091/27/2009 12:47:21 PMPPASS
Michael Phone #: ###-#### ok to final, signed coccupancy card, no esc this project
ELE09-00127 Electrical Rough-In1/26/20091/27/20091/27/2009 10:53:55 AMAPASS
leo Phone #: ###-#### corrections made, ric ok
ELE09-00105 Electrical Rough-In1/26/20091/27/20091/27/2009 10:32:32 AMAFAIL
after 9 please-joseph Phone #: ###-#### met owner, corrections 300.4 (A)&(D) 1/14" for edge of holes and nm cable shall be maintained, 210.52 (B)(2) circuits for outdoor recpt and light shall not be on dining room circuit, no esc this project
ELE08-02609 Conference1/26/20091/27/20091/27/2009 9:51:31 AMADONE
lee Phone #: ###-#### met owner, told that he must re-open building permit, looked at basement to see about ri for that part only, no esc this project
ELE08-00171 Final1/26/20091/27/20091/27/2009 9:12:22 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Kevin Perez ok to final, no card to sign, no esc this project
ELE09-00131 Final1/26/20091/27/20091/27/2009 8:27:23 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Bryan McLaughlin met contractor, ok to final, no esc this project