Inspections for the day of: Friday, January 27, 2012.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-02007 ELE-Aging Inspection1/27/20121/27/20122/2/2012 9:54:52 AM CANC
ELE12-00074 Permanent Service1/27/20121/27/20121/27/2012 3:07:00 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Lars Johnson 110.26(F)(2) remove a/c lines from below p/s for required clearence move guy kit up by weatherhead for adequate support of mast 230.28
ELE11-02106 Final1/26/20121/27/20121/27/2012 2:59:53 PMPPASS
Please call Jim for access code. Phone #: ###-#### >> Inspection requested via web by Paula Gratiot
ELE11-02239 Permanent Service1/26/20121/27/20121/27/2012 2:59:35 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Chris Weimar
p/s u/g new ok
ELE12-00154 Final1/27/20121/27/20121/27/2012 12:48:19 PMAPASS
ELE12-00154 Permanent Service1/26/20121/27/20121/27/2012 12:42:39 PMPPASS
This is an overhead riser ready for inspection Friday. Thanks Phone #: ###-#### >> Inspection requested via web by Paula Gratiot p/s o/h rec. ok
ELE11-01867 Final1/26/20121/27/20121/27/2012 11:39:44 AMAFAIL
Garage Code 8607 and 7373 Phone #: ###-#### >> Inspection requested via web by Therrin Robertson called correction posted 314.3 metallic fitting not allowed in nonmetallic box, 314.43 screws not allowed in in plastic box, 314.20 box shall be flush with combustible material
ELE12-00170 Conference1/26/20121/27/20121/27/2012 11:36:33 AMADONE
Bryan ###-#### ok
ELE12-00115 Electrical Rough-In1/26/20121/27/20121/27/2012 11:36:12 AMAPASS
soffit Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin soffits ok
ELE12-00114 Permanent Service1/26/20121/27/20121/27/2012 11:35:52 AMAPASS
Ryan is contact. Could you call contact number 15 or 20 minutes prior to being there so I can have somebody there to meet you? Thanks Phone #: ###-#### >> Inspection requested via web by Chris Chesnut p/s o/h new ok
ELE12-00099 Final1/26/20121/27/20121/27/2012 11:35:23 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Tyler Bowen
ELE10-01304 ELE-Aging Inspection1/27/20121/27/20121/27/2012 7:30:52 AM CANC
ELE11-02239 Rough-In Permanent Service1/26/20121/27/20121/26/2012 8:33:09 PMPCANC
Phone #: ###-#### >> Inspection requested via web by Chris Weimar Inspection cancelled from web by: Chris Weimar