Inspections for the day of: Tuesday, January 27, 2015.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-02631 Final1/27/20151/27/20151/28/2015 9:17:47 AMPCANC
House only seperate permit for floor heat check ele15-00115. House Final ok This edit was for a different permit and address
ELE15-00123 Final1/26/20151/27/20151/28/2015 9:13:39 AMANR
corrections made. Phone #: ###-#### Inspection requested via web by Randy Fletcher All terminations recessed in floor and cable secured in place.Check junction below stat remains accessible. Rough in ok cover
MIS14-00290 ELE-Conference1/27/20151/27/20151/28/2015 9:12:23 AMPDONE
Check for permit Drove by, no answer at door posted correction notice asking to please contact me concerning permit.
ELE14-02213 Electrical Rough-In1/27/20151/27/20151/27/2015 2:00:33 PMPPASS
Mike Phone #: ###-#### Front canopy lid and reception area wall rough in ok cover
ELE15-00115 Final1/27/20151/27/20151/27/2015 12:55:06 PMPFAIL
Phone #: ###-#### Inspection requested viweb by Therrin Robertson 424.99- A device provided by the manufacturer shall open all ungrounded conductors incase of a fault. Right stat test failed.
ELE13-00508 Final1/27/20151/27/20151/27/2015 11:10:07 AMPPASS
UL listing confirmed. Final ok
ELE13-00509 Final1/27/20151/27/20151/27/2015 11:06:44 AMPPASS
UL listing confirmed. Final ok
ELE13-00574 ELE-Aging Inspection1/27/20151/27/20151/27/2015 10:38:51 AM DONE
Drove by and inspected
ELE13-00574 Final1/27/20151/27/20151/27/2015 10:38:36 AMPPASS
UL listing and disconnecting means confirmed. Final ok
ELE12-02104 ELE-Aging Inspection1/27/20151/27/20151/27/2015 10:22:18 AM DONE
Still under construction
ELE15-00123 Electrical Rough-In1/27/20151/27/20151/27/2015 10:20:56 AMPPASS
All terminations recessed in floor. Check junction below stat remains accessible. Floor heat rough in ok cover
ELE14-03379 Final1/26/20151/27/20151/27/2015 10:12:59 AMAPASS
Shannon is the contact his cell no. is ###-#### Phone #: ###-#### Inspection requested via web by Shawna Gates Final ok
ELE15-00199 Permanent Service1/26/20151/27/20151/27/2015 9:10:01 AMAPASS
Please call Eric 30 mins before. Phone #: ###-#### Inspection requested via web by Eric Schroeder All existing circuits have been cut so they cannot be reused. Reconnect for temp power located below panel. p/s u/g rec ok
ELE15-00154 Electrical Rough-In1/26/20151/27/20151/27/2015 8:41:44 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton New panel room walls rough in ok cover