Inspections for the day of: Wednesday, January 27, 2016.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-02083 Final1/27/20161/27/20161/27/2016 2:06:06 PMPFAIL
Lockbox 4888, if you have any questions, please call Calvin with questions ###-####. Thank You.!! Phone #: ###-#### Inspection requested via web by Clay Morgan4-05-32 bco need box fixed with exposed thhn and cover required for receptacles in mason wall
ELE15-02083 Final1/27/20161/27/20161/27/2016 2:04:11 PMPCANC
Lockbox 4888, if you have any questions, please call Calvin with questions ###-####. Thank You.!! Phone #: ###-#### Inspection requested via web by Clay Morgan
ELE15-01283 Electrical Rough-In1/27/20161/27/20161/27/2016 1:53:34 PMPPASS
ready at 1 pm. thanks Phone #: ###-#### Inspection requested via web by Garrett Collins master bed and closet and pantry walls ok cover
ELE15-03497 Final1/27/20161/27/20161/27/2016 1:30:24 PMPPASS
Ark fault blank Phone #: ###-#### Inspection requested via web by Emmet Bushman corrections fixed
ELE15-03661 Permanent Service1/27/20161/27/20161/27/2016 1:21:07 PMPPASS
please call prior to inspection Phone #: ###-#### Inspection requested via web by BARRY KENDALL need to verify equipment grounding conductor has beed removed from termination cabinet to main I-line panel so there is no parellel path onto grounding conductor. p/s u/g n ok 2 ct meters needed
ELE13-01666 ELE-Aging Inspection1/27/20161/27/20161/27/2016 11:21:31 AM DONE
too busy
ELE12-00788 ELE-Aging Inspection1/27/20161/27/20161/27/2016 11:20:16 AM DONE
Talk with Jon he will be finishing soon. Waiting on homeowner to finish his work
ELE16-00212 Electrical Rough-In1/27/20161/27/20161/27/2016 10:48:37 AMAPASS
Someone should be there all day please call if you have any questions. Thanks Shaun ###-#### Phone #: ###-#### Inspection requested via web by Shaun Kirkman kitchen remodel ok cover
ELE16-00248 Electrical Rough-In1/26/20161/27/20161/27/2016 10:26:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Gene Wright u/g for well ok cover
ELE16-00221 Electrical Rough-In1/26/20161/27/20161/27/2016 9:31:14 AMAPASS
Contractor will be on site. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan basement remodel ok cover
ELE15-03552 Electrical Rough-In1/26/20161/27/20161/27/2016 9:16:50 AMAPASS
Underground. Phone #: ###-#### Inspection requested via web by Clint Tate underground from house to detached garage ok cover
ELE15-03858 Electrical Rough-In1/26/20161/27/20161/27/2016 9:04:33 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton bathrooms hard lids ok cover