Inspections for the day of: Friday, January 28, 2005.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Johnson
TitlePLM-INSPECTOR
Phone #794-9476
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM05-00250 Sprinkler (Final)1/27/20051/28/20051/28/2005 12:00:00 AMAPASS
renee; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
PLM04-03357 Water and/or Sewer1/27/20051/28/20051/28/2005 12:00:00 AMACANC
Contact Perry with questions; Phone #: ###-#### Internet Inspection Request from: Roger Patterson
PLM04-03357 Final1/27/20051/28/20051/28/2005 12:00:00 AMAPASS
Perry; Phone #: ###-#### Internet Inspection Request from: Jan Rice
PLM05-00181 Plumbing Rough-in1/27/20051/28/20051/28/2005 12:00:00 AMAPASS
Internet Inspection Request from: Kim Alderson
PLM04-00501 Final1/27/20051/28/20051/28/2005 12:00:00 AMAPART
Scheduled by a contractor via Hello! on 1/27/2005 at 11:22:04 PM. Contact: ###-####. upc 409.1 water closet bowls for public use to be elongated type with open front seat (2) need to provide a PVB on hand held shower at hydroco table (3) have all backflow devices tested and certified (4) provide clearance and acess for testing and maintenance and repair for double check,s located in wall 1/28/2005 11:36:43 AM
PLM04-03441 Final1/28/20051/28/20051/28/2005 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 1/28/2005 at 7:41:19 AM. Contact: ###-####.
PLM05-00256 Plumbing Rough-in1/28/20051/28/20051/28/2005 12:00:00 AMPFAIL
leo ###-#### in unit 8513- need to remove fernco coupling from 3 inch pipe in over head and replace with approved coupling 2- need to roll island sink vent connection to drain line above center line and support island sink vent in floor joist every 4 feet also need a few more hanger,s on drain lines in crawl in unit 8517 need to move water piping 12 inches away from can lighting in overhead in kitchen area and test failed on DWV . left notice and called contractor will recall when ready 1/28/2005 2:41:58 PM
PLM04-03265 Final1/28/20051/28/20051/28/2005 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 1/28/2005 at 11:13:38 AM. Contact: ###-####.
PLM05-00248 Plumbing Rough-in1/28/20051/28/20051/28/2005 12:00:00 AMPPASS
PLM05-00238 Plumbing Rough-in1/27/20051/28/20051/28/2005 12:00:00 AMPPART
Scheduled by a contractor via Hello! on 1/27/2005 at 6:32:22 PM. Contact: ###-####. correct all leaks and retest correct reverse grade in 3 inch under kit area in crawl space support pvc DWV as per table 3-2 in 2003 upc talked to contractor on job site will recall when ready 1/28/2005 4:27:28 PM