Inspections for the day of: Friday, January 28, 2005.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRick Jackson
TitleFIRE INSPECTOR
Phone #794-1981
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
FIR04-00601 FIR-Aging Inspection1/28/20051/28/20051/28/2005 12:00:00 AM PART
Laren will schedule this for next week 1/28/2005 7:53:58 AM
BLD04-01741 FIRE-Final Inspection1/28/20051/28/20051/28/2005 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 1/28/2005 at 7:07:03 AM. Contact: ###-####.
FIR04-00477 INSP-Alarm Testing1/27/20051/28/20051/28/2005 12:00:00 AMAFAIL
Let me know what time works for you so that I can know when to be there, and can schedule it with the General Contractor.; Phone #: ###-#### Internet Inspection Request from: Rick Groom Flow switch not working properly - cycles 1/28/2005 1:09:07 PM
BLD04-01222 FIRE-Final Inspection1/27/20051/28/20051/28/2005 12:00:00 AMAFAIL
###-#### No approved plans; talked to Dean and told him to have approved plans and reschedule - will need address and landing at street side exit 1/28/2005 10:55:58 AM
FIR05-00040 INSP-Final Inspection1/27/20051/28/20051/28/2005 12:00:00 AMAPASS
jim; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
BLD04-02313 FIRE-Final Inspection1/27/20051/28/20051/28/2005 12:00:00 AMAPART
###-#### - sam; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Temp Occupancy approver per Sam R for fire; post occupant load sign; certify extinguishers 1/28/2005 9:22:46 AM
BLD04-01063 FIRE-Conference1/27/20051/28/20051/28/2005 12:00:00 AMAPART
tim; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Location of manual pull for extinguishing system will be 10 ft from hood 1/28/2005 9:42:47 AM
FIR04-00605 INSP-Final Inspection1/27/20051/28/20051/28/2005 12:00:00 AMPFAIL
Scheduled by a contractor via Hello! on 1/27/2005 at 4:42:33 PM. Contact: ###-####.

All duct detectors were smoked and functioned properly. (the duct on the roof has an enclosure, needs to have holes drilled to allow air to circulate around the pc board)

All forward flow test valves were wired to the backflow preventer input...they will be disconnected.

Zone labeling needs to be changed.

East side of facility.

West riser room smoke and pull had addresses reversed.

East riser room backflow and main flow were wired incorrectly.

East water flow requires adjustment (> 90 sec), Simplex has been called, apparently something is wrong with the flow switch.

West side of facility, tested all tampers and waterflows, exceptable.
FIR04-00448 INSP-Final Inspection1/27/20051/28/20051/28/2005 12:00:00 AMPPASS
Contact: Vance - Needs around 2 PM - please call to confirm.; Phone #: ###-#### Internet Inspection Request from: Alicia Pauley UG riser has been corrected to allow heat to base of UG at sidewalk level; dry uprights installed 1/28/2005 2:06:15 PM
BLD04-02486 FIRE-Final Inspection1/28/20051/28/20051/28/2005 12:00:00 AMPPASS
greg; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
FIR04-00808 INSP-Alarm Testing1/28/20051/28/20051/28/2005 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 1/28/2005 at 8:39:10 AM. Contact: ###-####.
FIR05-00009 INSP-Sprinkler Rough-in1/28/20051/28/20051/28/2005 12:00:00 AMPFAIL
COVER INSPECTION; Phone #: ###-#### Internet Inspection Request from: Alicia Pauley No plans at job 1/28/2005 1:35:07 PM
FIR04-00546 INSP-Final Inspection1/28/20051/28/20051/28/2005 12:00:00 AMPFAIL
OH hydro okay; flow switch not working properly - cycles; forward flow of BFP okay 1/28/2005 1:08:42 PM
FIR04-00432 INSP-Final Inspection1/28/20051/28/20051/28/2005 12:00:00 AMPPASS
final okay 1/28/2005 2:07:05 PM
BLD03-02187 FIRE-Final Inspection1/28/20051/28/20051/28/2005 12:00:00 AMPPASS
BLD04-01386 FIRE-Final Inspection1/28/20051/28/20051/28/2005 12:00:00 AMPPASS
FIR04-00616 INSP-Final Inspection1/28/20051/28/20051/28/2005 12:00:00 AMPPASS
FIR04-00774 INSP-Conference1/27/20051/28/20051/28/2005 12:00:00 AMPCANC
loren; Phone #: ###-#### Internet Inspection Request from: Barbara Moore Tlaked to Loren and this was supposed to be canceled 1/28/2005 3:47:47 PM
MIS05-00011 FIR-Final1/27/20051/28/20051/27/2005 12:00:00 AMAPASS
dana; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD04-01772 FIRE-Conference1/27/20051/28/20051/27/2005 12:00:00 AMPCANC
Nate; Phone #: ###-#### Internet Inspection Request from: Jan Rice cancel due wrong inspection
BLD04-01771 FIRE-Conference1/27/20051/28/20051/27/2005 12:00:00 AMPCANC
Nate; Phone #: ###-#### Internet Inspection Request from: Jan Rice Note: wrong inspection