Inspections for the day of: Thursday, January 28, 2016.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-02052 ELE-Aging Inspection1/28/20161/28/20162/5/2016 2:47:43 PM PASS
Drove by and inspected
ELE12-01498 ELE-Aging Inspection1/28/20161/28/20162/2/2016 2:48:58 PM PASS
Still under construction
ELE16-00067 Final1/27/20161/28/20161/28/2016 3:00:54 PMPNH
Phone #: ###-#### Inspection requested via web by Jonathan Poot
Receptionists tryed for over 10 minutes to reach someone with key to area with out responce. Will recall.
ELE16-00134 Electrical Rough-In1/27/20161/28/20161/28/2016 2:59:27 PMPNH
Phone #: ###-#### Inspection requested via web by Jonathan Poot
Receptionists tryed for 10 minutes to contact owner for key with out responce. Will recall when available
ELE16-00156 Final1/28/20161/28/20161/28/2016 2:14:24 PMPPASS
Thank you please sign paper work. :) Phone #: ###-#### Inspection requested via web by Rick Beckman Final ok
ELE15-03960 Final1/28/20161/28/20161/28/2016 1:08:29 PMPPASS
Back garage door open. Phone #: ###-#### Inspection requested via web by Barbara Szurgot Final ok
ELE16-00264 Electrical Rough-In1/28/20161/28/20161/28/2016 12:30:33 PMPPASS
Walls and hard ceilings. Lock box combo is 1618 Phone #: ###-#### Inspection requested via web by Lee VanSchoiack
Rough in ok cover
ELE16-00269 Permanent Service1/28/20161/28/20161/28/2016 11:56:29 AMPPASS
call for access ###-#### Phone #: ###-#### Inspection requested via web by John VanZandt
Ground rod and plumbing bond present. Call for final after circuit directory complete.
p/s u/g rec ok
ELE15-01912 Final1/27/20161/28/20161/28/2016 11:33:36 AMAPASS
Please call ahead for access - Earle Phone #: ###-#### Final ok
ELE15-03960 Final1/27/20161/28/20161/28/2016 10:57:03 AMANH
Corrections made. Any questions please call Shawn. Phone #: ###-#### Inspection requested via web by Barbara Szurgot
Door locked no answer at door
ELE16-00262 Electrical Rough-In1/27/20161/28/20161/28/2016 10:08:23 AMAPASS
contact Jared for access ###-#### Phone #: ###-#### Inspection requested via web by michael hunt
Office walls and grid in office and room across from office rough in ok cover
ELE16-00260 Permanent Service1/27/20161/28/20161/28/2016 9:40:16 AMAFAIL
call for access ###-#### Phone #: ###-#### Inspection requested via web by John VanZandt
250.24(A)- A premises wiring system supplied by a grounded AC service shall have a grounding electrode conductor connected to grounded conductor at service.
250.52(A)(1)- Underground metal water pipe if present shall be part of grounding electode system.
250.53(A)(2)- A single rod or pipe shall have supplemental electrode installed.
4-05-32- Code violations not to be retained.
334.30- SER cable installed under house in crawl shall be supported with supports not to exceed 4 1/2'.
ELE16-00250 Temporary Service1/26/20161/28/20161/28/2016 8:36:34 AMAPASS
Phone #: ###-#### Inspection requested via web by TOM BICANDI t/s u/g n ok
ELE16-00251 Temporary Service1/26/20161/28/20161/28/2016 8:36:00 AMAPASS
Phone #: ###-#### Inspection requested via web by TOM BICANDI t/s u/g n ok
ELE16-00252 Temporary Service1/26/20161/28/20161/28/2016 8:35:26 AMAPASS
Phone #: ###-#### Inspection requested via web by TOM BICANDI t/s u/g n ok
ELE13-00104 Final1/27/20161/28/20161/27/2016 6:48:47 PMACANC
call mike with any questions,
contact Jared for access ###-#### Phone #: ###-#### >> Inspection requested via web by michael hunt Inspection cancelled from web by: michael hunt