Inspections for the day of: Monday, January 28, 2019.
Number of inspections: 6
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-00334 Rough-In Permanent Service1/28/20191/28/20191/28/2019 2:35:24 PMPPASS
Dave Phone #: ###-####
Level 2 attic furnace boxes not trimmed at time of inspection. Rough in ok cover p/s u/g n ok
ELE18-04784 Electrical Rough-In1/25/20191/28/20191/28/2019 12:21:09 PMAFAIL
Pad conduits Phone #: ###-#### Inspection requested via web by Tom Jenkins
314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible. Boxes, conduit bodies, and handhole enclosures shall be installed so that the wiring contained in them can be rendered accessible without removing any part of the building or structure or, in underground circuits, without excavating sidewalks, paving, earth, or other substance that is to be used to establish the finished grade.
Ant eater pond actuators located too deep in ground box to be accessible.
ELE19-00283 Temporary Service1/25/20191/28/20191/28/2019 10:04:44 AMAPASS
Phone #: ###-#### Inspection requested via web by Rowdy Monroe t/s u/g n ok
ELE19-00282 Temporary Service1/25/20191/28/20191/28/2019 9:46:50 AMAPASS
Phone #: ###-#### Inspection requested via web by Rowdy Monroe t/s u/g n ok
ELE18-04236 Final1/25/20191/28/20191/28/2019 9:43:21 AMAFAIL
Call for access code, thank you. Phone #: ###-#### Inspection requested via web by kim grundhauser
210.8- All GFCI devices shall be located in readily accessible locations. Christmas receptacle located in out entry above 6'7".
ELE18-04164 Final1/27/20191/28/20191/28/2019 9:42:13 AMAFAIL
Call for access code thank you Phone #: ###-#### Inspection requested via web by kim grundhauser
210.8- GFCI devices shall be located in readily accessible locations. Soffit receptacle west garage.
410.10(D)- Luminaires located in shower stall shall be rated for wet locations. Master shower confirm rating of trim and lamp.