MEC19-04440 Final1/27/20201/28/20201/28/2020 3:43:44 PMPNH
Homeowner was supposed to reschedule. Has not responded to calls or certified letter. Please go by and try to inspect. Phone #: ###-#### Inspection requested via web by Mary LaFayette- no one home- left notice- permit will expire next aging if homeowner doesnt call for inspection
MEC19-04836 Final1/27/20201/28/20201/28/2020 3:06:43 PMPPASS
HOME TILL 3 30 Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING- furnace only co ok
MEC20-00351 Rough-in1/27/20201/28/20201/28/2020 2:16:43 PMPFAIL
Phone #: ###-#### Inspection requested via web by Arcadio Martinez
1- need city approved man j onsite -ducting doesnt match man j onsite
2- dryer duct to termination box 2nd floor needs sealed
3- need to seal 20 to 16 supply reducer in chase and all mastic needs to maintain thickness of a nickel all joints crimps can be seen 1st and 2nd floor chases
4- need to fix all rips and tears in arma flex in crawl bare copper showingmultiple place

left notice front window
MEC20-00351 Pressure Test1/27/20201/28/20201/28/2020 2:12:40 PMPPASS
Phone #: ###-#### Inspection requested via web by Arcadio Martinez- 20lb gas pass tagged meter loction- 5lb flue
MEC19-04429 Final1/27/20201/28/20201/28/2020 1:30:09 PMPNH
CALL MUHAMMAD WHEN ON YOUR WAY ###-#### Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING- phone number listed does not work- went by rang doorbell and knocked no one home- no access
MEC20-00391 Final1/28/20201/28/20201/28/2020 1:14:06 PMPPASS
Phone #: ###-#### Inspection requested via web by max sanders- final ok- installed 1 R/A register and relocated supply- card signed
MEC20-00386 Final1/27/20201/28/20201/28/2020 11:05:17 AMAPART
CHRIS IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- need to remove 2 flex connectos on gas line to abandoned RTUs and plug off to final this permit out- talked with GC onsite and Chris by phone- will look at this on other Mech permit inspection this week
MEC20-00379 Final1/27/20201/28/20201/28/2020 10:45:16 AMAPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace only co ok
MEC20-00178 Final1/21/20201/28/20201/28/2020 10:14:06 AMAPASS
Please call Josh prior to arrival. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace only co ok
MEC19-04422 Final1/27/20201/28/20201/28/2020 9:34:40 AMAFAIL
THEY ARE HOME ALL MORNING ###-#### Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING- furnace a/c coil co ok- need locking caps on a/c service ports - need to seal gas piping thru foundation at meter location- send pic for reinspect
MEC19-04104 Final1/23/20201/28/20201/28/2020 9:06:07 AMAPASS
Please call Ray on your way over. Thank you! Phone #: ###-#### Inspection requested via web by Misty Merry- furnace a/c coil co locking caps ok
MEC20-00169 Final1/23/20201/28/20201/28/2020 8:33:27 AMAPASS
David needs a 30 minute pre-call prior to going out as he will be meeting you there. ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace a/c coil co locking caps ok
MEC19-02924 Mec-Aging Inspection1/28/20201/28/20201/28/2020 7:46:08 AM FAIL