Inspections for the day of: Wednesday, January 29, 2014.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-00788 ELE-Aging Inspection1/29/20141/29/20141/29/2014 3:44:46 PM DONE
Still under construction
ELE14-00238 Final1/29/20141/29/20141/29/2014 3:38:37 PMPPASS
Confirm ceiling rough-in and final please.
Only work performed was relocating light fixtures and Fire Alarm.
Thank you Phone #: ###-#### >> Inspection requested via web by Dan Wright Final ok
ELE14-00238 Final1/29/20141/29/20141/29/2014 3:37:58 PMPPASS
Confirm ceiling rough-in and final please.
Only work performed was relocating light fixtures and Fire Alarm.
Thank you Phone #: ###-#### >> Inspection requested via web by Dan Wright Ceiling rough in ok cover
ELE13-02057 Electrical Rough-In1/29/20141/29/20141/29/2014 2:54:06 PMPPASS
Robert Ceiling Cover. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy 6th floor E. of elevator 1 corridor to north ceiling rough in ok cover GFCI for drinking fountain confirmed, Bathrooms complete.
ELE13-03507 Final1/29/20141/29/20141/29/2014 2:23:26 PMPPASS
Phone #: ###-#### >> Inspection requested via web by steve ragan Final ok
ELE13-03507 Permanent Service1/29/20141/29/20141/29/2014 1:41:17 PMPPASS
Phone #: ###-#### >> Inspection requested via web by steve ragan p/s u/g n ok
ELE14-00205 Final1/29/20141/29/20141/29/2014 1:35:26 PMPPASS
Installed solar PV on roof, AC disconnects located at exterior main panel and meter service. Phone #: ###-#### >> Inspection requested via web by Matthew Dunay Solar Final ok
ELE14-00205 Electrical Rough-In1/29/20141/29/20141/29/2014 1:20:03 PMPPASS
Installed solar PV on roof, AC disconnects located at exterior main panel and meter service. Phone #: ###-#### >> Inspection requested via web by Matthew Dunay Solar rough in ok
ELE14-00218 Permanent Service1/29/20141/29/20141/29/2014 1:18:43 PMPPASS
Final as well Phone #: ###-#### >> Inspection requested via web by Kevin Cowgill Solar rough in ok p/s solar ok
ELE14-00218 Final1/29/20141/29/20141/29/2014 1:18:30 PMPPASS
Final as well Phone #: ###-#### >> Inspection requested via web by Kevin Cowgill Solar final ok
ELE14-00180 Permanent Service1/29/20141/29/20141/29/2014 12:37:28 PMPPASS
Service Only Phone #: ###-#### >> Inspection requested via web by Rowdy Monroe
42k AIC rated main confirmed. p/s u/g n ok
ELE14-00157 Electrical Rough-In1/28/20141/29/20141/29/2014 10:35:02 AMAPASS
Need Uffer inspection. If you have any questions please contact Craig Timmons. Phone #: ###-#### >> Inspection requested via web by Vicki Moore Rough in ok cover
ELE13-02810 Final1/29/20141/29/20141/29/2014 9:49:20 AMAPASS
Final inspect at Jacksons. Contact is Justin Bieker. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery Final ok
ELE14-00233 Electrical Rough-In1/28/20141/29/20141/29/2014 9:28:43 AMAPART
Contact: Wes Powell Phone #: ###-#### >> Inspection requested via web by Deb Gooden Correction on water heater in basement that access to fused disconnect is not readily accessible. Called Danny with RME to correct ###-####. Basement wall rough in ok cover
ELE13-02783 Electrical Rough-In1/28/20141/29/20141/29/2014 9:26:27 AMAPASS
Contact: Jeremy Thornock Phone #: ###-#### >> Inspection requested via web by Deb Gooden All grid rough in ok
ELE13-02469 Electrical Rough-In1/28/20141/29/20141/29/2014 9:25:32 AMAPASS
Contact: Jeremy Thornock Phone #: ###-#### >> Inspection requested via web by Deb Gooden all grid rough in ok cover
ELE13-02787 Electrical Rough-In1/28/20141/29/20141/29/2014 9:23:57 AMAPASS
Contact: Jeremy Thornock Phone #: ###-#### >> Inspection requested via web by Deb Gooden All grid ok except 2 conf and large conference rest rough in ok cover