Inspections for the day of: Thursday, January 29, 2015.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-01498 ELE-Aging Inspection1/29/20151/29/20151/30/2015 4:12:52 PM DONE
Still under construction
ELE15-00139 Conference1/29/20151/29/20151/29/2015 2:50:30 PMPDONE
Shane Phone #: ###-#### Discussed location and type of special service gear for sign. Asked contractor to contact planning and zoning for special location and type of gear used. Reassigned ELE15-00139, permit for sign service and underground, to sign BLD14-02542
ELE15-00203 Electrical Rough-In1/29/20151/29/20151/29/2015 1:54:15 PMPPASS
Underground cover for Sign on the south east corner of the Edwards complex. In Front of the Cracker Barrel. Danny is the on site contact. Phone #: ###-#### Inspection requested via web by Buster Bowen Underground for sign and power associated with sign rough in ok cover.
ELE14-03157 Final1/29/20151/29/20151/29/2015 1:21:35 PMPFAIL
6365 code Phone #: ###-#### Inspection requested via web by Dan Rohl
334.12(B)(4)- NM cable shall not be used in a damp or wet location. In flex to AC unit.
314.20- Where boxes are installed in a tile wall and are recessed 1/4" or more extension rengs shall be used.
ELE14-03128 Final1/29/20151/29/20151/29/2015 1:19:02 PMPFAIL
6365 code Phone #: ###-#### Inspection requested via web by Dan Rohl
210.52(C)(1)- For counter top areas deeper than 18" from back of sink to wall receptacles shall be install for wall space.
314.20- Where boxes are installed in tile wall and are recessed 1/4" or more extension rengs shall be installed.
334.12(B)(4)- NM calbe shall not be used in a damp or wet location. In flex to AC unit.
110.3- Correct cover shall be used to cover back patio outdoor receptacle.
ELE14-03350 Electrical Rough-In1/28/20151/29/20151/29/2015 11:57:13 AMAFAIL
Ron Phone #: ###-#### 314.16- Boxes shall have sufficient size to provide free air space for enclosed conductors.
300.4- Bored holes that do not maintain 1 1/4" shall have nail plates.
* Receptacle outlets located in garage shall be above 18" minimum.
ELE15-00222 Permanent Service1/28/20151/29/20151/29/2015 11:22:00 AMAFAIL
There hasn''t been a meter at this location for over a year, Idaho Power is requiring an inspection of the service before powering.
The ACCESS CODE is 0802
any questions please let me know, thx, TW. Phone #: ###-####
Inspection requested via web by Stephen Kren
250.50- All grounding electrodes present shall be used. Complete bonding of metal water pipe at water heater.
334.30 NM cable shall be secured within 12" above panel.
334.116- Outer sheath shall be present and enter box by minimum of 1/4". Remove branch circuit to 240 volt receptacle in garage.
* Repair flex at furnace.
ELE14-02082 Final1/29/20151/29/20151/29/2015 10:35:21 AMPPASS
Mike Phone #: ###-#### Corrections made Final ok
ELE15-00131 Final1/28/20151/29/20151/29/2015 10:34:21 AMAPASS
AM inspection. Contact Bob @ ###-#### Phone #: ###-#### Inspection requested via web by Kristopher Wilson Final ok
ELE14-02082 Final1/29/20151/29/20151/29/2015 10:33:46 AMPPASS
Corrections made. Final ok
ELE15-00232 Electrical Rough-In1/28/20151/29/20151/29/2015 10:04:15 AMAPASS
Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Wall rough in ok cover
ELE15-00235 Temporary Service1/29/20151/29/20151/29/2015 9:50:29 AMAPASS
Phone #: ###-#### Inspection requested via web by Jerry Moore t/s u/g n ok
ELE15-00080 Permanent Service1/28/20151/29/20151/29/2015 9:31:50 AMAPASS
Inspection requested via web by Terry Scott p/s o/h rec ok
ELE15-00217 Electrical Rough-In1/28/20151/29/20151/29/2015 9:22:42 AMAPASS
Jerad Phone #: ###-#### Master bath and closet and kitchen additions rough in ok cover
ELE12-01006 Final1/29/20151/29/20151/29/2015 9:06:53 AMAFAIL
Kitchen remodel ###-#### 8:45am
314.20- Where box is recessed 1/4" or more in tile a extension ring shall be installed.
406.11- Receptacles installed in kitchen area shall be tamper resistant type.
ELE15-00221 Permanent Service1/29/20151/29/20151/29/2015 8:23:27 AMAPASS
There hasn''t been a meter at this location for over a year, Idaho Power is requiring an inspection of the service before powering.
the ACCESS CODE is 2704, thx Phone #: ###-#### Inspection requested via web by Stephen Kren p/s u/g rec ok
ELE15-00221 Final1/29/20151/29/20151/29/2015 8:23:08 AMPPASS
There hasn''t been a meter at this location for over a year, Idaho Power is requiring an inspection of the service before powering.
the ACCESS CODE is 2704, thx Phone #: ###-#### Inspection requested via web by Stephen Kren Service reconnect final ok
ELE15-00221 Permanent Service1/28/20151/29/20151/29/2015 6:43:35 AMACANC
There hasn''t been a meter at this location for over a year, Idaho Power is requiring an inspection of the service before powering.
The ACCESS CODE is 2904
Any questions please let me know, thx, TW. Phone #: ###-#### >> Inspection requested via web by Stephen Kren Inspection cancelled from web by: Stephen Kren
ELE15-00231 Rough-In Permanent Service1/28/20151/29/20151/28/2015 3:50:30 PMAPASS
Phone #: ###-#### Inspection requested via web by TOM BICANDI// rough in ok to cover p/s u/g n ok