ELE15-00226
| Final | 1/28/2015 | 1/29/2015 | 1/29/2015 3:29:42 PM | P | NR |
|
|
Used as conference with contractor, moved inspection to tomorrow. Contractor has been notified that there is knob and tube wiring that is in contact with insulation, and that is a know violation of use of product. Contractor to discuss this with homeowner.
|
ELE15-00238
| Final | 1/29/2015 | 1/29/2015 | 1/29/2015 1:54:09 PM | P | PASS |
|
|
Final OK
|
ELE15-00238
| Permanent Service | 1/29/2015 | 1/29/2015 | 1/29/2015 1:53:42 PM | P | PASS |
|
|
You can text me ahead of time and I can meet you there. I''m 20 or 30 minutes away. Phone #: ###-#### Inspection requested via web by Kevin Cowgill PS, UG, RC, OK
|
ELE15-00178
| Final | 1/29/2015 | 1/29/2015 | 1/29/2015 1:16:13 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Final OK
|
ELE14-03280
| Final | 1/29/2015 | 1/29/2015 | 1/29/2015 12:49:10 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Andrea Creek 210.52 C(3) Peninsular Countertop Spaces. At least one receptacle outlet shall be installed at each peninsular countertop space with a long dimension of 600 mm (24 in.) or greater and a short dimension of 300 mm (12 in.) or greater. A peninsular countertop is measured from the connecting edge. 110.12 Mechanical Execution of Work. Electrical equipment shall be installed in a neat and workmanlike manner. Front weather proof outlet box pulling out of wall, misc. loose receptacles through home
|
ELE15-00187
| Rough-In Permanent Service | 1/26/2015 | 1/29/2015 | 1/29/2015 12:05:00 PM | P | PASS |
|
|
Please make inspection for first on yout afternoon docket. to turn home owner power back on in the afternoon. Phone #: ###-#### Inspection requested via web by Lori Stout
Perm service OK, need panel schedule for subpanel at final RI, PS, UG, OK
|
ELE15-00034
| Electrical Rough-In | 1/28/2015 | 1/29/2015 | 1/29/2015 10:27:01 AM | A | PASS |
|
|
Inspect on Grid for Ceiling Phone #: ###-#### Inspection requested via web by David Nelson RI ceiling cover OK
|
ELE15-00045
| Electrical Rough-In | 1/28/2015 | 1/29/2015 | 1/29/2015 10:26:37 AM | A | PASS |
|
|
Inspect on Grid for Ceiling Phone #: ###-#### Inspection requested via web by David Nelson RI Ceiling cover ok
|
ELE15-00230
| Temporary Service | 1/29/2015 | 1/29/2015 | 1/29/2015 10:10:45 AM | P | PASS |
|
|
TS, UG, N, OK
|
ELE15-00230
| Final | 1/28/2015 | 1/29/2015 | 1/29/2015 10:10:10 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Need Temp, not final
|
ELE15-00201
| Temporary Service | 1/28/2015 | 1/29/2015 | 1/29/2015 9:57:29 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Zane Robertson TS, UG, N, OK
|
ELE15-00228
| Rough-In Permanent Service | 1/28/2015 | 1/29/2015 | 1/29/2015 9:20:28 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk RI OK PS, UG, N, OK
|
ELE15-00220
| Permanent Service | 1/28/2015 | 1/29/2015 | 1/29/2015 9:00:42 AM | A | PASS |
|
|
There hasn''t been a meter at this location for over a year, Idaho Power is requiring an inspection of the service before powering. the ACCESS CODE is 1040 thx Phone #: ###-#### Inspection requested via web by Stephen Kren 210.4 B) Disconnecting Means. Each multiwire branch circuit shall be provided with a means that will simultaneously disconnect all ungrounded conductors at the point where the branch circuit originates. PS, UG, RC, OK
|
ELE15-00053
| Electrical Rough-In | 1/28/2015 | 1/29/2015 | 1/28/2015 3:11:40 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Eric Brown RI Ok to cover upstairs and cantilever decks
|