Inspections for the day of: Thursday, January 29, 2015.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorCevyn Recla
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-00226 Final1/28/20151/29/20151/29/2015 3:29:42 PMPNR
Used as conference with contractor, moved inspection to tomorrow.
Contractor has been notified that there is knob and tube wiring that is in contact with insulation, and that is a know violation of use of product. Contractor to discuss this with homeowner.
ELE15-00238 Final1/29/20151/29/20151/29/2015 1:54:09 PMPPASS
Final OK
ELE15-00238 Permanent Service1/29/20151/29/20151/29/2015 1:53:42 PMPPASS
You can text me ahead of time and I can meet you there. I''m 20 or 30 minutes away. Phone #: ###-#### Inspection requested via web by Kevin Cowgill
PS, UG, RC, OK
ELE15-00178 Final1/29/20151/29/20151/29/2015 1:16:13 PMPPASS
Phone #: ###-#### Inspection requested via web by Lee VanSchoiack
Final OK
ELE14-03280 Final1/29/20151/29/20151/29/2015 12:49:10 PMPFAIL
Phone #: ###-#### Inspection requested via web by Andrea Creek
210.52 C(3) Peninsular Countertop Spaces. At least one receptacle
outlet shall be installed at each peninsular countertop space
with a long dimension of 600 mm (24 in.) or greater and a
short dimension of 300 mm (12 in.) or greater. A peninsular
countertop is measured from the connecting edge.
110.12 Mechanical Execution of Work. Electrical equipment
shall be installed in a neat and workmanlike manner. Front weather proof outlet box pulling out of wall, misc. loose receptacles through home
ELE15-00187 Rough-In Permanent Service1/26/20151/29/20151/29/2015 12:05:00 PMPPASS
Please make inspection for first on yout afternoon docket. to turn home owner power back on in the afternoon. Phone #: ###-#### Inspection requested via web by Lori Stout

Perm service OK, need panel schedule for subpanel at final
RI, PS, UG, OK
ELE15-00034 Electrical Rough-In1/28/20151/29/20151/29/2015 10:27:01 AMAPASS
Inspect on Grid for Ceiling Phone #: ###-#### Inspection requested via web by David Nelson
RI ceiling cover OK
ELE15-00045 Electrical Rough-In1/28/20151/29/20151/29/2015 10:26:37 AMAPASS
Inspect on Grid for Ceiling Phone #: ###-#### Inspection requested via web by David Nelson
RI Ceiling cover ok
ELE15-00230 Temporary Service1/29/20151/29/20151/29/2015 10:10:45 AMPPASS
TS, UG, N, OK
ELE15-00230 Final1/28/20151/29/20151/29/2015 10:10:10 AMACANC
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
Need Temp, not final
ELE15-00201 Temporary Service1/28/20151/29/20151/29/2015 9:57:29 AMAPASS
Phone #: ###-#### Inspection requested via web by Zane Robertson
TS, UG, N, OK
ELE15-00228 Rough-In Permanent Service1/28/20151/29/20151/29/2015 9:20:28 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk
RI OK PS, UG, N, OK
ELE15-00220 Permanent Service1/28/20151/29/20151/29/2015 9:00:42 AMAPASS
There hasn''t been a meter at this location for over a year, Idaho Power is requiring an inspection of the service before powering.
the ACCESS CODE is 1040 thx Phone #: ###-#### Inspection requested via web by Stephen Kren
210.4 B) Disconnecting Means. Each multiwire branch circuit
shall be provided with a means that will simultaneously
disconnect all ungrounded conductors at the point where
the branch circuit originates.
PS, UG, RC, OK
ELE15-00053 Electrical Rough-In1/28/20151/29/20151/28/2015 3:11:40 PMAPASS
Phone #: ###-#### Inspection requested via web by Eric Brown
RI Ok to cover upstairs and cantilever decks