Inspections for the day of: Monday, January 3, 2005.
Number of inspections: 7
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE02-03131 Final12/30/20041/3/20051/3/2005 12:00:00 AMAPASS
Please let Cathy know if final is approved. Thanks! ok to final 1/3/2005 2:18:10 PM
ELE04-04098 Rough-In Permanent Service12/30/20041/3/20051/3/2005 12:00:00 AMAPASS
Internet Inspection Request from: Bob Glenn ok to cover. p/s u/g n ok. Called and told comtr. he needs some nailplates in dining area. 1/3/2005 8:20:34 AM
ELE00-03794 Final12/30/20041/3/20051/3/2005 12:00:00 AMAFAIL
Tony-call 1/2 hr before you go; Phone #: ###-#### Internet Inspection Request from: Jan Rice 210.70(A)(2)(a) light shall be installed in garage, 110.22 Disconnecting means shall be identified,200.7(A)(1) White wire shall not be used for phase condutor,110.3 Fuse panel shall not mix breakers and fuses. Panel not suitable for use,344.30(A) Metal conduit shall be strapped within 3' of panel 1/3/2005 9:45:18 AM
ELE04-04074 Rough-In Permanent Service12/31/20041/3/20051/3/2005 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 12/31/2004 at 9:11:02 AM. Contact: ###-####. corrections made. p/s o/h exst ok 1/3/2005 8:39:17 AM
ELE04-04098 Rough-In Permanent Service1/3/20051/3/20051/3/2005 12:00:00 AMPCANC
Internet Inspection Request from: Bob Glenn contr called in twice 1/3/2005 4:08:42 PM
ELE04-02797 Final1/3/20051/3/20051/3/2005 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 1/3/2005 at 10:27:09 AM. Contact: ###-####. called contr to add flex strap ,strap emt going to wall, and cover duct det. box. ok to final 1/3/2005 1:29:47 PM
ELE04-03914 Electrical Rough-In1/3/20051/3/20051/3/2005 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 1/3/2005 at 11:28:36 AM. Contact: ###-####. told owner to repair sheath in one place, 11/4 wire spacing in 2 places,and to use insulating type bushing on cans. ok to cover walls and ceiling. 1/3/2005 1:09:57 PM