MEC19-04419
| Final | 1/2/2020 | 1/3/2020 | 1/3/2020 3:49:03 PM | P | PASS |
|
|
AC: 2018 Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok
|
MEC19-04326
| Final | 1/3/2020 | 1/3/2020 | 1/3/2020 3:15:43 PM | P | FAIL |
|
|
GARAGE CD 1234 Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- approved man j onsite 2- condensate to washer box needs completed 3- seal exterior gas line penetration at meter
|
MEC19-04327
| Final | 1/3/2020 | 1/3/2020 | 1/3/2020 3:14:34 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- seal exterior gas line penetration at meter 2- condensate to washer box needs completed 3- approved man j onsite
|
MEC20-00025
| Final | 1/3/2020 | 1/3/2020 | 1/3/2020 2:57:18 PM | P | PASS |
|
|
Please call Aleks on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace only co ok
|
MEC19-05755
| Rough-in | 1/3/2020 | 1/3/2020 | 1/3/2020 2:17:49 PM | P | PART |
|
|
Please call Ryan with questions at ###-####, we are working with the city to get our manual J approved. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum- R/I will pass when gas piping is determined if needed to new dryer vent location may need to be retested if line is ran- Ryan is aware of this and will check in on this- Ok for insulation only DO NOT SHEETROCK- meter will be tagged once gas piping resolved- inert tape need installed thru wall or sleeve with pvc between stucco and piping- building inspector is aware of insulation only at this time
|
MEC19-04745
| Final | 1/2/2020 | 1/3/2020 | 1/3/2020 1:31:41 PM | P | PASS |
|
|
###-####- after 1 pm- wood fireplace insert and flue ok
|
MEC19-05777
| Final | 12/30/2019 | 1/3/2020 | 1/3/2020 12:52:13 PM | P | PASS |
|
|
Field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney- 20lb gas pass- unit heater ok
|
MEC20-00002
| Rough-in | 1/2/2020 | 1/3/2020 | 1/3/2020 11:29:48 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Tim Petsche- R/I ok- ok for cover- call in final when ready
|
MEC19-01679
| Rough-in | 12/31/2019 | 1/3/2020 | 1/3/2020 11:11:40 AM | A | PART |
|
|
cover and grease duct Phone #: ###-#### Inspection requested via web by Amanda Farnsworth- 1st and 2nd layer firewrap ok- excluding hood connections- area A B and C corridirs ok for ceiling tiles- area A rms 111 110 109 ok for cover
|
MEC19-04327
| Final | 1/3/2020 | 1/3/2020 | 1/3/2020 10:10:51 AM | P | CANC |
|
|
GARAGE CD 1234 Phone #: ###-#### >> Inspection requested via web by Oleg Chervak Inspection cancelled from web by: Oleg Chervak
|
MEC19-04544
| Final | 1/3/2020 | 1/3/2020 | 1/3/2020 10:10:41 AM | P | CANC |
|
|
MEC AND FIREPL; CARAGE CD 3484 Phone #: ###-#### >> Inspection requested via web by Oleg Chervak Inspection cancelled from web by: Oleg Chervak
|
MEC19-04801
| Final | 1/3/2020 | 1/3/2020 | 1/3/2020 10:02:02 AM | A | PASS |
|
|
MEC AND FIREPL GARAGE CD 7530 Phone #: ###-#### Inspection requested via web by Oleg Chervak- final ok
|
MEC19-04259
| Final | 12/31/2019 | 1/3/2020 | 1/3/2020 9:14:26 AM | A | FAIL |
|
|
Lockbox Code: CHE Builder ###-#### HVAC ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks 1- range hood needs installed and sealed nothing installed 2- outside air in furnace closet needs insulated to R6
|
MEC19-05467
| Final | 12/27/2019 | 1/3/2020 | 1/3/2020 8:32:40 AM | A | PASS |
|
|
Please inspect in the AM and call the homeowner when on way: Lauren ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace a/c coil co locking caps ok
|
MEC19-00597
| Mec-Aging Inspection | 1/3/2020 | 1/3/2020 | 1/3/2020 7:46:04 AM | | DONE |
|
|
|
MEC19-00597
| DOC - Permit Expired | 1/3/2020 | 1/3/2020 | 1/3/2020 7:45:53 AM | A | PASS |
|
|
no calls- no activity- permit expired
|