ELE03-01999
| Final | 1/26/2004 | 1/30/2004 | 1/30/2004 12:00:00 AM | A | PASS |
|
|
WE ARE LOOKING FOR A FINAL ON THIS PROJECT AND THE HOMEOWNER WILL BE THERE TO LET YOU IN. HOME OWNER NAME IS RAY HOOD. THANK YOU; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH ok 1/30/2004 8:44:23 AM
|
ELE04-00146
| Rough-In Permanent Service | 1/29/2004 | 1/30/2004 | 1/30/2004 12:00:00 AM | A | FAIL |
|
|
Joe; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes cor. posted called 314.16 box fill everywhere, 300.4 nail plates and 11/4" 422.15 and 210.23(A) needs #12 for vacuum outlet on 20 amp circuits and vacuum outlets not allowed on kit. circuit, replace damaged 12/2 romex stairs landing garage wall 1/30/2004 11:31:47 AM
|
ELE04-00161
| Permanent Service | 1/29/2004 | 1/30/2004 | 1/30/2004 12:00:00 AM | A | PASS |
|
|
dan ###-#### p/s o/h rec. ok 1/30/2004 10:16:08 AM
|
ELE04-00241
| Electrical Rough-In | 1/29/2004 | 1/30/2004 | 1/30/2004 12:00:00 AM | A | PART |
|
|
j-kel ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie walls for computer trainer center 1/30/2004 9:15:14 AM
|
ELE04-00007
| Final | 1/29/2004 | 1/30/2004 | 1/30/2004 12:00:00 AM | A | PASS |
|
|
bob; Phone #: ###-#### Internet Inspection Request from: Annette Moore ok 1/30/2004 9:54:20 AM
|
ELE04-00260
| Conference | 1/29/2004 | 1/30/2004 | 1/30/2004 12:00:00 AM | A | PART |
|
|
###-#### brian ok 1/30/2004 11:49:17 AM
|
ELE04-00234
| Temporary Service | 1/29/2004 | 1/30/2004 | 1/30/2004 12:00:00 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: William Zerfas
t/s o/h new ok 1/30/2004 8:05:37 AM
|
ELE04-00269
| Permanent Service | 1/30/2004 | 1/30/2004 | 1/30/2004 12:00:00 AM | P | PASS |
|
|
dave ; Phone #: ###-#### Internet Inspection Request from: Annette Moore
p/s o/h rec. ok 1/30/2004 3:03:09 PM
|
ELE04-00227
| Electrical Rough-In | 1/30/2004 | 1/30/2004 | 1/30/2004 12:00:00 AM | P | PASS |
|
|
andy ; Phone #: ###-#### Internet Inspection Request from: Annette Moore new back of house ok 1/30/2004 12:47:20 PM
|
ELE04-00280
| Temporary Service | 1/30/2004 | 1/30/2004 | 1/30/2004 12:00:00 AM | P | PASS |
|
|
###-#### mike
t/s u/g new ok 1/30/2004 1:25:53 PM
|
ELE04-00110
| Final | 1/30/2004 | 1/30/2004 | 1/30/2004 12:00:00 AM | P | PASS |
|
|
we are relocating existing bathroom switches and gfci receptacle. we are alo adding a fan/lt in the bathroom. In the kitchen we are replacing existing outlets with gfci receptacles.; Phone #: ###-#### Internet Inspection Request from: Joe Thomas ok 1/30/2004 2:04:58 PM
|
ELE03-00160
| Final | 1/30/2004 | 1/30/2004 | 1/30/2004 12:00:00 AM | P | CANC |
|
|
|
ELE04-00160
| Final | 1/30/2004 | 1/30/2004 | 1/30/2004 12:00:00 AM | P | PASS |
|
|
ok correction made 1/30/2004 3:27:39 PM
|