BLD05-02408
| BLD-Framing/Rough-in | 1/30/2006 | 1/30/2006 | 1/30/2006 5:01:18 PM | P | FAIL |
|
|
John; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Needs to sheet rock around canlight at vestibule. Bloow patches to be connected back to framimg member. Fire caulk around penetrations.
|
BLD05-02210
| BLD-Final | 1/30/2006 | 1/30/2006 | 1/30/2006 3:38:34 PM | P | NR |
|
|
Scheduled by a contractor via Hello! on 1/30/2006 at 7:24:56 AM. Contact: ###-####. Needs plumbing final.
|
BLD05-02611
| BLD-Framing/Rough-in | 1/30/2006 | 1/30/2006 | 1/30/2006 3:36:17 PM | P | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Stephen Renberg. Provide hangars on remaining trusses in garage at 427 side. Truss membrane penetration at 1hr wall not allowed, not as per plan. 5/8 type X gyp is required behind tubs and concealled space. Also provide wall assemblly for correct attachement of type x.
|
BLD05-01833
| BLD-Energy code compliance | 1/30/2006 | 1/30/2006 | 1/30/2006 2:30:11 PM | P | FAIL |
|
|
Brian; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Complete lateral bracing, header required over opening at C1 truss bearing, justify girder truss support were hangar was deleted. L brace gable end.
|
BLD05-01835
| BLD-Energy code compliance | 1/30/2006 | 1/30/2006 | 1/30/2006 2:28:19 PM | P | FAIL |
|
|
Brian; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Lateral bracing not complete. Header required over opening at C1 truss bearing. Justify girder support were hangar was deleted. L brace gable end.
|
BLD05-01560
| BLD-Framing/Rough-in | 1/30/2006 | 1/30/2006 | 1/30/2006 2:22:03 PM | P | PASS |
|
|
Casey; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Needs to complete the air seal package prior to insulating.
|
BLD05-02621
| BLD-Framing/Rough-in | 1/27/2006 | 1/30/2006 | 1/30/2006 10:33:00 AM | A | NR |
|
|
Chris -- for resinspection; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. All items on c/n not complete.
|
BLD05-01335
| BLD-Final | 1/27/2006 | 1/30/2006 | 1/30/2006 10:26:30 AM | A | PASS |
|
|
Ben -- call 1st for access; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
|
BLD05-03050
| BLD-Other | 1/29/2006 | 1/30/2006 | 1/30/2006 10:06:33 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 1/29/2006 at 8:23:31 PM. Contact: ###-####. ok to cover pending mech and elec insp.
|
BLD05-02089
| BLD-Footing | 1/27/2006 | 1/30/2006 | 1/30/2006 9:44:36 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 1/27/2006 at 3:23:37 PM. Contact: ###-####. east and south footings.
|
BLD05-00962
| BLD-Final | 1/28/2006 | 1/30/2006 | 1/30/2006 9:15:35 AM | A | PASS |
|
|
Internet Inspection Request from: Carey Allen
|
BLD05-01947
| BLD-Final | 1/28/2006 | 1/30/2006 | 1/30/2006 9:05:16 AM | A | FAIL |
|
|
Internet Inspection Request from: Carey Allen. Complete grading, does not have 24 inches from footing to finish grade.
|
BLD05-00962
| DOC - Permit Finaled | 1/30/2006 | 1/30/2006 | 1/30/2006 12:00:00 AM | P | PASS |
|
|
|
BLD05-01335
| DOC - Permit Finaled | 1/30/2006 | 1/30/2006 | 1/30/2006 12:00:00 AM | P | PASS |
|
|
|
BLD05-03379
| BLD-Footing | 1/30/2006 | 1/30/2006 | 1/30/2006 12:00:00 AM | P | PASS |
|
|
Reinforcement installed. footing and stemwall placed at same time.
|