Inspections for the day of: Wednesday, January 30, 2008.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-01827 Final1/30/20081/30/20081/30/2008 4:14:51 PMPPASS
ok to final, shack already gone, meter has red tag, so need new permit for next year
ELE06-02869 Final1/30/20081/30/20081/30/2008 3:49:45 PMPPASS
talked with contractor, ok to final
ELE08-00235 Electrical Rough-In1/30/20081/30/20081/30/2008 2:37:59 PMPFAIL
jeremiah - please call 1/2 hr prior to inspection Phone #: ###-#### called Hume, bad number, met owner showed what wrong, left correction notice, nec 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 300.14 at least 6" free conductor measured from point in box where cable emerges shall be left for splices, BCC shall not install devices before inspection
ELE08-00214 Electrical Rough-In1/30/20081/30/20081/30/2008 1:37:48 PMPPASS
Scheduled by a contractor via Hello! on 1/30/2008 at 7:09:59 AM. Contact: ###-####. walls only ok to cover
ELE07-01088 Electrical Rough-In1/30/20081/30/20081/30/2008 12:44:25 PMPCANC
shawn Note above ceiling Phone #: ###-#### see conference
ELE07-01088 Conference1/30/20081/30/20081/30/2008 12:36:14 PMPDONE
shawn Note above ceiling Phone #: ###-#### talked about strapping conduit exiting wall and fixture whips
ELE08-00230 Final1/29/20081/30/20081/30/2008 10:22:46 AMACANC
mike Note: please call 1/2 hr prior to inspection for access Phone #: ###-#### called contractor, see nr
ELE08-00230 Permanent Service1/29/20081/30/20081/30/2008 9:51:50 AMANR
mike Note: please call 1/2 hr prior to inspection for access Phone #: ###-#### called contractor, they didn't do water pipe ground and need to come back, will call for pm inspection, contractor not available for inspection
ELE08-00226 Electrical Rough-In1/29/20081/30/20081/30/2008 9:22:45 AMANR
Please call Mike if needed for walls only rough in inspection. Phone #: ###-#### Internet Inspection Request from: Loren Ramsey builder changing walls, fee due
ELE08-00225 Electrical Rough-In1/29/20081/30/20081/30/2008 9:02:35 AMAPASS
Please call Mike if needed for walls only rough in inspection. Phone #: ###-#### Internet Inspection Request from: Loren Ramsey walls only anop ok to cover