Inspections for the day of: Wednesday, January 30, 2019.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-00313 Temporary Service1/30/20191/30/20191/30/2019 2:24:30 PMPPASS
Mucho Phone #: ###-#### t/s u/g n ok
ELE18-04363 Final1/30/20191/30/20191/30/2019 1:39:36 PMPPASS
garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
ELE18-04439 Final1/30/20191/30/20191/30/2019 1:03:28 PMPPASS
Final for cell site.
Contact Seth VanWassenhove
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Final ok
ELE18-04429 Final1/30/20191/30/20191/30/2019 1:03:04 PMPPASS
Mucho Phone #: ###-#### final ok
ELE18-04276 Electrical Rough-In1/30/20191/30/20191/30/2019 12:01:45 PMPPASS
Rough in for garage and utility room addition. Please call Wayne at the number listed or Kaden at ###-#### when on the way. Phone #: ###-#### Inspection requested via web by William Salts Garage and utility room only ok to cover
ELE19-00369 Permanent Service1/29/20191/30/20191/30/2019 11:19:42 AMAPASS
service change Phone #: ###-#### Inspection requested via web by danny perrine p/s o/h rec ok
ELE18-02234 Final1/29/20191/30/20191/30/2019 11:01:13 AMAPASS
lock code 2531 call bob if there is any questions ###-#### Phone #: ###-#### Inspection requested via web by Bob Glenn final ok
ELE19-00375 Electrical Rough-In1/29/20191/30/20191/30/2019 10:30:02 AMAFAIL
To access the area you need to drive on the east side of the property. When your on the east side of the Lot the back south east corner of the fence is an opening, you can go through there then you will see the new framing. if your confused please call me and I can help you. thx Phone #: ###-#### Inspection requested via web by Neal Rumsey 314.29. Boxes and wiring contained in them shall be accessible.(Switch and Junction box to the left of counter top)
ELE18-04536 Electrical Rough-In1/29/20191/30/20191/30/2019 9:59:47 AMAPASS
Phone #: ###-#### Inspection requested via web by Mark M remaining walls ok to cover
ELE18-02506 Final1/29/20191/30/20191/30/2019 9:59:16 AMAPASS
Phone #: ###-#### Inspection requested via web by Mark M Final ok
ELE18-04722 Final1/29/20191/30/20191/30/2019 9:25:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Lance Litchy Final ok
ELE18-04219 Electrical Rough-In1/29/20191/30/20191/29/2019 2:20:39 PMAPASS
Cover inspection any questions please call Louis at ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller underground from house to pool ok to cover