PLM19-05212
| Final | 1/29/2020 | 1/30/2020 | 1/30/2020 3:15:20 PM | P | FAIL |
|
|
Code for lock box on back parking lot door is 950# Phone #: ###-#### Inspection requested via web by Mark Kelso. 1. Install tempering valves on all public lavatories. 2 North ADA restroom requires a right hand flush water closet.
|
PLM19-05461
| Plumbing Rough-in | 1/30/2020 | 1/30/2020 | 1/30/2020 2:46:53 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by robert goodson
|
PLM20-00190
| Water Heater Final | 1/28/2020 | 1/30/2020 | 1/30/2020 2:31:53 PM | P | PASS |
|
|
Please see homeowner, Sandy Evans, on site. Please call her when headed out ###-####. For questions, please contact plumber Scott Ferguson ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Scott Ferguson
|
PLM20-00350
| Plumbing Rough-in | 1/30/2020 | 1/30/2020 | 1/30/2020 2:18:06 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Michael Klaas. Heat tape isn't an approved assembly for freeze protection in an attic. Pipe must be attached to the joist, visqueen under the pipe, insulation bats over the pipe attached to the joists.
|
PLM20-00383
| Plumbing Rough-in | 1/30/2020 | 1/30/2020 | 1/30/2020 2:15:53 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
PLM20-00366
| Water and/or Sewer | 1/30/2020 | 1/30/2020 | 1/30/2020 1:29:08 PM | P | CANC |
|
|
Wii call when ready Phone #: ###-#### Inspection requested via web by bob pond water service
|
PLM20-00366
| DOC - Permit Finaled | 1/30/2020 | 1/30/2020 | 1/30/2020 1:28:52 PM | P | PASS |
|
|
|
PLM19-04946
| Groundwork | 1/29/2020 | 1/30/2020 | 1/30/2020 11:03:21 AM | A | PASS |
|
|
Ground work inside home Phone #: ###-#### Inspection requested via web by Bill Calkins
|
PLM20-00350
| Plumbing Rough-in | 1/29/2020 | 1/30/2020 | 1/30/2020 9:33:27 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Michael Klaas 1. Cannot run the water lines in the cold attic without freeze protection assembly. 2. An expansion tank will be required on trim. 3. Verify ADA WC r-in.
|
PLM20-00188
| Final | 1/29/2020 | 1/30/2020 | 1/30/2020 9:10:45 AM | A | FAIL |
|
|
John Rowe is Landlord ###-####, he states the door is unlocked on the Robert Street side of building 820, basement connects to 821 Wade. Please call our office if you arrive onsite and are not able to access for a 3rd time. Phone #: ###-#### Inspection requested via web by Lynn Mallory The T&P drain cannot run up hill Use proper filltings to change direction and drill a hole at the low point by the valve. 2. The double check valve must be certified..It hasn't bee tested since 2005
|