Inspections for the day of: Thursday, January 30, 2020.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM19-05212 Final1/29/20201/30/20201/30/2020 3:15:20 PMPFAIL
Code for lock box on back parking lot door is 950# Phone #: ###-#### Inspection requested via web by Mark Kelso.
1. Install tempering valves on all public lavatories.
2 North ADA restroom requires a right hand flush water closet.
PLM19-05461 Plumbing Rough-in1/30/20201/30/20201/30/2020 2:46:53 PMPPASS
Phone #: ###-#### Inspection requested via web by robert goodson
PLM20-00190 Water Heater Final1/28/20201/30/20201/30/2020 2:31:53 PMPPASS
Please see homeowner, Sandy Evans, on site. Please call her when headed out ###-####. For questions, please contact plumber Scott Ferguson ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Scott Ferguson
PLM20-00350 Plumbing Rough-in1/30/20201/30/20201/30/2020 2:18:06 PMPFAIL
Phone #: ###-#### Inspection requested via web by Michael Klaas.
Heat tape isn't an approved assembly for freeze protection in an attic.
Pipe must be attached to the joist, visqueen under the pipe, insulation bats over the pipe attached to the joists.
PLM20-00383 Plumbing Rough-in1/30/20201/30/20201/30/2020 2:15:53 PMPPASS
Phone #: ###-#### Inspection requested via web by Brian Johansen
PLM20-00366 Water and/or Sewer1/30/20201/30/20201/30/2020 1:29:08 PMPCANC
Wii call when ready Phone #: ###-#### Inspection requested via web by bob pond water service
PLM20-00366 DOC - Permit Finaled1/30/20201/30/20201/30/2020 1:28:52 PMPPASS
PLM19-04946 Groundwork1/29/20201/30/20201/30/2020 11:03:21 AMAPASS
Ground work inside home Phone #: ###-#### Inspection requested via web by Bill Calkins
PLM20-00350 Plumbing Rough-in1/29/20201/30/20201/30/2020 9:33:27 AMAFAIL
Phone #: ###-#### Inspection requested via web by Michael Klaas
1. Cannot run the water lines in the cold attic without freeze protection assembly.
2. An expansion tank will be required on trim.
3. Verify ADA WC r-in.
PLM20-00188 Final1/29/20201/30/20201/30/2020 9:10:45 AMAFAIL
John Rowe is Landlord ###-####, he states the door is unlocked on the Robert Street side of building 820, basement connects to 821 Wade. Please call our office if you arrive onsite and are not able to access for a 3rd time. Phone #: ###-#### Inspection requested via web by Lynn Mallory
The T&P drain cannot run up hill Use proper filltings to change direction and drill a hole at the low point by the valve.
2. The double check valve must be certified..It hasn't bee tested since 2005