MEC19-05531
| Final | 1/31/2020 | 1/31/2020 | 1/31/2020 4:13:46 PM | P | FAIL |
|
|
Door Should be open, if is not, there is a key under the seat of the dump truck that is park outside. Manual J and, duct blast and balance should be by the furnace. Phone #: ###-#### Inspection requested via web by Nicolas Barajas - high and low combustion air grilles mech closet - locking caps for A/C - landscraping rocks are covering line set outside
|
MEC20-00350
| Final | 1/29/2020 | 1/31/2020 | 1/31/2020 3:37:43 PM | P | PASS |
|
|
Homeowner Joe Braun ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace ac coil co ok
|
MEC20-00358
| Rough-in | 1/30/2020 | 1/31/2020 | 1/31/2020 3:23:02 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - all exhaust fan connections need sealed sveral location through out site - 1405 supply trunk in attic needs insulated
|
MEC20-00358
| Pressure Test | 1/30/2020 | 1/31/2020 | 1/31/2020 3:21:57 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - 1403 5lb flue pressure tests fail and one gauge needs to be a 15lb 1405 2 5lb flue test ok 1405&1403 20lb gas pressure tests ok - tagged meter location
|
MEC20-00439
| Rough-in | 1/31/2020 | 1/31/2020 | 1/31/2020 2:52:24 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE - R/I ok
|
MEC19-05075
| Rough-in | 1/31/2020 | 1/31/2020 | 1/31/2020 2:45:43 PM | P | PASS |
|
|
Roof duct sealed for insulation. Francisco is the contact. Phone #: ###-#### Inspection requested via web by stan lillquist - one RTU duct seal for roof duct ok - need to see duct seam right at roof curb sealed
|
MEC20-00334
| Final | 1/30/2020 | 1/31/2020 | 1/31/2020 2:18:22 PM | P | FAIL |
|
|
Please give me a call prior to showing up so I can be onsite to be able to get you access to the house.
Thank you Phone #: ###-#### Inspection requested via web by Geff Blecha - mini splits ok - need approved UL listed connectors for pvc jacketed mc cables
|
MEC20-00431
| Pressure Test | 1/30/2020 | 1/31/2020 | 1/31/2020 2:06:33 PM | P | FAIL |
|
|
Gas pressure test and final fireplace inspection. Please call Randy prior to arrival Phone #: ###-#### Inspection requested via web by Jamee Shoecraft - CSST needs sleeved at fireplace - CSST needs support in crawl space - fireplace needs clearances to combustibles on top and sides - 20lb gas ok not sure where connection will be but need to see tie in at final
|
MEC20-00396
| Pressure Test | 1/31/2020 | 1/31/2020 | 1/31/2020 1:15:37 PM | P | FAIL |
|
|
Eddie- please call for access Phone #: ###-#### - gas pressure test under 20lb - add fireplace to permit - sleeve CSST at fireplace and use approved termination support - wrap any exposed stainless CSST outside once tied in to main gas line
|
MEC19-04498
| Final | 1/30/2020 | 1/31/2020 | 1/31/2020 12:22:54 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Lindsey Stegemann - final ok
|
MEC20-00429
| Rough-in | 1/31/2020 | 1/31/2020 | 1/31/2020 12:15:41 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - Man J doesn't match equipment or ducting upstairs - all duct work needs sealed - duct work in crawl needs insulated
|
MEC19-05789
| Final | 1/27/2020 | 1/31/2020 | 1/31/2020 11:24:36 AM | A | PASS |
|
|
Please call prior to arrival if possible. Sally is POC. Phone #: ###-#### Inspection requested via web by Andrea Grigsby - furnace ac coil co ok
|
MEC20-00209
| Final | 1/28/2020 | 1/31/2020 | 1/31/2020 11:12:27 AM | A | PASS |
|
|
This is a Flue Pressure and Final Inspect. Please meet our installer at home at 11:00 AM. Contact for Right Now is Mary ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - no need for flue test - furnace only co ok
|
MEC20-00150
| Rough-in | 1/30/2020 | 1/31/2020 | 1/31/2020 11:00:24 AM | A | FAIL |
|
|
Jason - possible leak in outside hose, previous rough in failed. Phone #: ###-#### - tie in point of gas line has a leak and homeowner has shut off meter. - will need to re test line to ensure no leaks - CSST needs sleeved where entering house - where stainless steel is exposed at connections will need to be re wrapped with approved materials
|
MEC20-00439
| Rough-in | 1/30/2020 | 1/31/2020 | 1/31/2020 10:37:09 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE - insulation shield on b vent 1st floor - line set needs supported in crawl
|
MEC20-00439
| Pressure Test | 1/30/2020 | 1/31/2020 | 1/31/2020 10:36:30 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE - 5lb flue ok - 20lb gas ok - tagged meter location
|
MEC19-04324
| Final | 1/29/2020 | 1/31/2020 | 1/31/2020 10:20:57 AM | A | PASS |
|
|
Please call Glenn 1st thing in the morning with an ETA so that he can meet you onsite for access. ###-####
Alt# Yvonne ###-#### if needed. Phone #: ###-#### Inspection requested via web by Yvonne Bowman - final ok
|
MEC19-04904
| Final | 1/30/2020 | 1/31/2020 | 1/31/2020 10:15:14 AM | A | FAIL |
|
|
Mini split installed for addition above garage. Ductwork added for addition on main level. Phone #: ###-#### Inspection requested via web by jeremy wanders - both A/C's need weather tight conduit/ A/C needs locking caps - range vent needs to be smooth walled pipe - new b vent for furnace and water heater needs 1" clearances at ceiling - need listing of comm wire to new A/C and approved connector
|
MEC20-00059
| Pressure Test | 1/30/2020 | 1/31/2020 | 1/31/2020 9:50:44 AM | A | FAIL |
|
|
if questions call Nolan @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann - need City of Boise approved prints onsite for gas piping pressure test
|
MEC19-04758
| Final | 1/30/2020 | 1/31/2020 | 1/31/2020 9:34:48 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Sheldon Lebow - unit 202, 207, 304 fireplace final ok - will, sign occ card once all mech permits are finaled
|
MEC19-01922
| Final | 1/28/2020 | 1/31/2020 | 1/31/2020 9:21:20 AM | A | FAIL |
|
|
Call when on the way to ensure home owner is home. Phone #: ###-#### Inspection requested via web by Dan McFate - co ok -wet switch and primary too close to furnace vent. Change out single wall for b vent to achieve clearances. threaded pvc fittings for condensate need sealed so they wont leak
|
MEC19-05159
| Final | 1/31/2020 | 1/31/2020 | 1/31/2020 8:41:59 AM | P | CANC |
|
|
>> Inspection requested via web by Loren Bailey Inspection cancelled from web by: Loren Bailey
|
MEC19-03717
| Final | 1/30/2020 | 1/31/2020 | 1/31/2020 8:02:49 AM | A | PASS |
|
|
JAYSON IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER - final ok
|
MEC19-03048
| Mec-Aging Inspection | 1/31/2020 | 1/31/2020 | 1/31/2020 8:01:13 AM | | FAIL |
|
|
Permit has not been active since being issued on 7-16-19. Schedule inspection with owner if work is finished. Permit will expired at next mechanical aging inspection if not active.
|