Inspections for the day of: Friday, January 31, 2020.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-05531 Final1/31/20201/31/20201/31/2020 4:13:46 PMPFAIL
Door Should be open, if is not, there is a key under the seat of the dump truck that is park outside. Manual J and, duct blast and balance should be by the furnace. Phone #: ###-####
Inspection requested via web by Nicolas Barajas
- high and low combustion air grilles mech closet - locking caps for A/C
- landscraping rocks are covering line set outside
MEC20-00350 Final1/29/20201/31/20201/31/2020 3:37:43 PMPPASS
Homeowner Joe Braun ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace ac coil co ok
MEC20-00358 Rough-in1/30/20201/31/20201/31/2020 3:23:02 PMPFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves
- all exhaust fan connections need sealed sveral location through out site
- 1405 supply trunk in attic needs insulated
MEC20-00358 Pressure Test1/30/20201/31/20201/31/2020 3:21:57 PMPFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves
- 1403 5lb flue pressure tests fail and one gauge needs to be a 15lb
1405 2 5lb flue test ok
1405&1403 20lb gas pressure tests ok
- tagged meter location
MEC20-00439 Rough-in1/31/20201/31/20201/31/2020 2:52:24 PMPPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
- R/I ok
MEC19-05075 Rough-in1/31/20201/31/20201/31/2020 2:45:43 PMPPASS
Roof duct sealed for insulation. Francisco is the contact. Phone #: ###-#### Inspection requested via web by stan lillquist
- one RTU duct seal for roof duct ok
- need to see duct seam right at roof curb sealed
MEC20-00334 Final1/30/20201/31/20201/31/2020 2:18:22 PMPFAIL
Please give me a call prior to showing up so I can be onsite to be able to get you access to the house.

Thank you Phone #: ###-#### Inspection requested via web by Geff Blecha
- mini splits ok
- need approved UL listed connectors for pvc jacketed mc cables
MEC20-00431 Pressure Test1/30/20201/31/20201/31/2020 2:06:33 PMPFAIL
Gas pressure test and final fireplace inspection. Please call Randy prior to arrival Phone #: ###-#### Inspection requested via web by Jamee Shoecraft
- CSST needs sleeved at fireplace
- CSST needs support in crawl space
- fireplace needs clearances to combustibles on top and sides
- 20lb gas ok not sure where connection will be but need to see tie in at final
MEC20-00396 Pressure Test1/31/20201/31/20201/31/2020 1:15:37 PMPFAIL
Eddie- please call for access Phone #: ###-####
- gas pressure test under 20lb
- add fireplace to permit
- sleeve CSST at fireplace and use approved termination support
- wrap any exposed stainless CSST outside once tied in to main gas line
MEC19-04498 Final1/30/20201/31/20201/31/2020 12:22:54 PMPPASS
Phone #: ###-#### Inspection requested via web by Lindsey Stegemann
- final ok
MEC20-00429 Rough-in1/31/20201/31/20201/31/2020 12:15:41 PMPFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart
- Man J doesn't match equipment or ducting upstairs
- all duct work needs sealed
- duct work in crawl needs insulated
MEC19-05789 Final1/27/20201/31/20201/31/2020 11:24:36 AMAPASS
Please call prior to arrival if possible. Sally is POC. Phone #: ###-#### Inspection requested via web by Andrea Grigsby
- furnace ac coil co ok
MEC20-00209 Final1/28/20201/31/20201/31/2020 11:12:27 AMAPASS
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 11:00 AM. Contact for Right Now is Mary ###-####
Phone #: ###-#### Inspection requested via web by Mary LaFayette
- no need for flue test
- furnace only co ok
MEC20-00150 Rough-in1/30/20201/31/20201/31/2020 11:00:24 AMAFAIL
Jason - possible leak in outside hose, previous rough in failed. Phone #: ###-####
- tie in point of gas line has a leak and homeowner has shut off meter.
- will need to re test line to ensure no leaks
- CSST needs sleeved where entering house
- where stainless steel is exposed at connections will need to be re wrapped with approved materials
MEC20-00439 Rough-in1/30/20201/31/20201/31/2020 10:37:09 AMAFAIL
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
- insulation shield on b vent 1st floor
- line set needs supported in crawl
MEC20-00439 Pressure Test1/30/20201/31/20201/31/2020 10:36:30 AMAPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
- 5lb flue ok
- 20lb gas ok
- tagged meter location
MEC19-04324 Final1/29/20201/31/20201/31/2020 10:20:57 AMAPASS
Please call Glenn 1st thing in the morning with an ETA so that he can meet you onsite for access. ###-####

Alt# Yvonne ###-#### if needed. Phone #: ###-#### Inspection requested via web by Yvonne Bowman
- final ok
MEC19-04904 Final1/30/20201/31/20201/31/2020 10:15:14 AMAFAIL
Mini split installed for addition above garage. Ductwork added for addition on main level. Phone #: ###-#### Inspection requested via web by jeremy wanders
- both A/C's need weather tight conduit/ A/C needs locking caps
- range vent needs to be smooth walled pipe
- new b vent for furnace and water heater needs 1" clearances at ceiling
- need listing of comm wire to new A/C and approved connector
MEC20-00059 Pressure Test1/30/20201/31/20201/31/2020 9:50:44 AMAFAIL
if questions call Nolan @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
- need City of Boise approved prints onsite for gas piping pressure test
MEC19-04758 Final1/30/20201/31/20201/31/2020 9:34:48 AMAPASS
Phone #: ###-#### Inspection requested via web by Sheldon Lebow
- unit 202, 207, 304 fireplace final ok
- will, sign occ card once all mech permits are finaled
MEC19-01922 Final1/28/20201/31/20201/31/2020 9:21:20 AMAFAIL
Call when on the way to ensure home owner is home. Phone #: ###-#### Inspection requested via web by Dan McFate
- co ok
-wet switch and primary too close to furnace vent. Change out single wall for b vent to achieve clearances. threaded pvc fittings for condensate need sealed so they wont leak
MEC19-05159 Final1/31/20201/31/20201/31/2020 8:41:59 AMPCANC
>> Inspection requested via web by Loren Bailey Inspection cancelled from web by: Loren Bailey
MEC19-03717 Final1/30/20201/31/20201/31/2020 8:02:49 AMAPASS
JAYSON IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
- final ok
MEC19-03048 Mec-Aging Inspection1/31/20201/31/20201/31/2020 8:01:13 AM FAIL
Permit has not been active since being issued on 7-16-19. Schedule inspection with owner if work is finished. Permit will expired at next mechanical aging inspection if not active.