Inspections for the day of: Wednesday, January 4, 2006.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-04525 Electrical Rough-In1/4/20061/4/20061/4/2006 4:07:57 PMPFAIL
ken ; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles cor. do not cover, called 210.52(A&B) needs out in new bedrm 2ft wall, all outlets in din rm shall be kit circuit, 210.52(C) countertop outlet spacing, 314.17 replace boxes with broken clamps, 250.148 splice all equip grds together at boxes, 250.52(A)(1) grd u/g water pipe 5ft300.10&12 4 locknuts for rigid nipple p/s subpanel, 300.4(A)(1)(D) all locations, 110.12 seal all unused KOs no tin can lids to be used 230.28 guy kit mast,312.5 conn for GEC, remove GEC from subpanel
ELE05-03958 ELE-Aging Inspection1/4/20061/4/20061/4/2006 3:52:58 PM PART
wsuc
ELE06-00031 Rough-In Permanent Service1/4/20061/4/20061/4/2006 2:52:12 PMPPASS
darrell ###-#### r/i ok p/s u/g new ok
ELE05-04607 Electrical Rough-In1/4/20061/4/20061/4/2006 2:03:45 PMPFAIL
please call 30 min prior to meet//Warren; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa cor. met contractor BCC no violations retained, all wiring installed and p/s, done without permit, shall be corrected to meet 2005 NEC, uncover all wiring covered before inspection, wiring in kitchen and bath shall meet spacing for countertops and walls , and circuit requirements
ELE05-02682 Final1/4/20061/4/20061/4/2006 12:55:31 PMAPASS
GARAGE CODE IS 1296 (ENTER); Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack ok
ELE05-04665 Rough-In Permanent Service1/4/20061/4/20061/4/2006 12:39:03 PMPFAIL
Charlie; Phone #: ###-#### Internet Inspection Request from: Melyne Davis
correction not made 300.4(A)(1)&(D) all locations from inside or outside edges called
ELE05-03982 Final1/3/20061/4/20061/4/2006 11:33:55 AMAPASS
Garage code is either 1234 or 8607; Phone #: ###-#### Internet Inspection Request from: Joe Thomas
ELE05-04663 Rough-In Permanent Service1/3/20061/4/20061/4/2006 10:59:07 AMAFAIL
Contact Todd Stewart; Phone #: ###-#### Internet Inspection Request from: HARVEY REYNA cor called 110.26(F) (2) 3ft clearence needed in front of p/s remove post and gate called
ELE05-03739 Final1/3/20061/4/20061/4/2006 10:33:36 AMAPASS
This is for final, please call mike K. said there was no underground inspection but this was done months ago.; Phone #: ###-#### Internet Inspection Request from: Daniel Gamboa ok by J Schmer for 2 outside branch circuits to single bilding (garage) this time only we are checking into it further
ELE05-04629 Rough-In Permanent Service1/3/20061/4/20061/4/2006 9:44:25 AMAFAIL
larry; Phone #: ###-#### Internet Inspection Request from: Barbara Moore cor. met contractor 210.52(A&B) needs outlet kit wall by pantry door, and upstairs along rail, 300.4(A)(1)&(D) high and low voltages, 314.16 box fill every where, 250.148 grd all metal boxes, 250.122 needs #12 equip grd for #12 circuits
ELE05-04325 Rough-In Permanent Service1/3/20061/4/20061/4/2006 8:37:46 AMAPART
DAN nOTE: UNDERGROUND; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles u/g feeders, and phone, catv only