Inspections for the day of: Wednesday, January 4, 2017.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-00185 ELE-Aging Inspection1/4/20171/4/20171/11/2017 10:33:14 AM DONE
Called and left message
ELE16-03767 Final1/4/20171/4/20171/4/2017 12:23:06 PMPFAIL
Phone #: ###-#### Inspection requested via web by Darryn Coburn
AFCI protection for all devices located in bedrooms(smokes)
ELE16-01314 Final1/3/20171/4/20171/4/2017 11:44:37 AMPPASS
Please call adam wright @###-#### an hour in advance or with as much notice as possible. Phone #: ###-#### Inspection requested via web by Tye Thomas

Final for restroom and lift station ok
ELE17-00011 Permanent Service1/3/20171/4/20171/4/2017 11:43:56 AMPPASS
Electrician-Ralph Horsley Phone #: ###-#### Inspection requested via web by Kenneth R. Horsley
p/s u/g rec ok i meter
ELE16-03799 Electrical Rough-In1/4/20171/4/20171/4/2017 11:00:45 AMPPASS
Conference room ceiling Phone #: ###-#### Inspection requested via web by Kevin Burke
Conference room ceiling only ok cover
ELE16-03957 Electrical Rough-In1/3/20171/4/20171/4/2017 10:21:52 AMAPASS
The rest of the open walls for cover. Refer ; pantry bumpout. Also kitchen switching on opposite side. Phone #: ###-#### Inspection requested via web by Cindie Swaim
Pantry wall ok cover
ELE12-02853 Final1/3/20171/4/20171/4/2017 9:15:01 AMAPASS
Phone #: ###-#### Inspection requested via web by William Andrews
Final for floor heat on patio ok
ELE16-02626 Final1/3/20171/4/20171/4/2017 8:56:59 AMAFAIL
Lock box is beside front steps and hose spigot. Key code is 2173. Phone #: ###-#### Inspection requested via web by Paula Gratiot
314.20 Box extenders required for kitchen
210.8 All 120v receptacles in kitchen shall have GFCI protection
406.4 tamper proof recpetacles required when changed out
ELE16-04157 Electrical Rough-In1/3/20171/4/20171/3/2017 8:39:33 AMAPASS
Phone #: ###-#### Inspection requested via web by Patrick Paz
Final for sevice change only ok