ELE04-02476
| Final | 1/4/2005 | 1/5/2005 | 1/5/2005 12:00:00 AM | A | PASS |
|
|
darrell; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok to final 1/5/2005 8:52:35 AM
|
ELE04-04052
| Temporary Service | 1/4/2005 | 1/5/2005 | 1/5/2005 12:00:00 AM | A | FAIL |
|
|
Daniel; Phone #: ###-#### Internet Inspection Request from: Jan Rice called owner and left correction notice. BCC shall post job id sticker. 250.24(A) shall gound grounding electrode conductor to grounded service conductor 1/5/2005 8:27:37 AM
|
ELE04-04116
| Rough-In Permanent Service | 1/5/2005 | 1/5/2005 | 1/5/2005 12:00:00 AM | A | PASS |
|
|
Internet Inspection Request from: Bob Glenn ok to cover, p/s u/g n ok 1/5/2005 9:27:11 AM
|
ELE04-04115
| Rough-In Permanent Service | 1/5/2005 | 1/5/2005 | 1/5/2005 12:00:00 AM | A | PASS |
|
|
THIS ONE WILL BE READY AFTER 10:00 THIS MORNING. THEY ARE JUST MAKING IT UP RIGHT NOW.THANKS BILL Internet Inspection Request from: Bob Glenn ok to cover, p/s u/g n ok 1/5/2005 9:39:29 AM
|
ELE04-04089
| Final | 1/4/2005 | 1/5/2005 | 1/5/2005 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 1/4/2005 at 9:23:25 AM. Contact: ###-####. ok to final 1/5/2005 8:04:51 AM
|
ELE05-00029
| Permanent Service | 1/4/2005 | 1/5/2005 | 1/5/2005 12:00:00 AM | A | PASS |
|
|
john ###-#### 250.86 ground conduit out of panel, 352.30(A) strap conduit within 3' 0f panel. Called contractor. p/s o/h exst ok 1/5/2005 10:35:39 AM
|
ELE05-00030
| Final | 1/4/2005 | 1/5/2005 | 1/5/2005 12:00:00 AM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Dana Moyer ok to final 1/5/2005 1:22:10 PM
|
ELE04-03814
| Final | 1/5/2005 | 1/5/2005 | 1/5/2005 12:00:00 AM | P | PASS |
|
|
THIS IS READY NOW I MISSED PUTTING IT IN THIS MORNING.THANKS BILL Internet Inspection Request from: Bob Glenn ok to final 1/5/2005 2:39:39 PM
|
ELE04-03723
| Electrical Rough-In | 1/5/2005 | 1/5/2005 | 1/5/2005 12:00:00 AM | P | PART |
|
|
Scheduled by a contractor via Hello! on 1/5/2005 at 9:17:12 AM. Contact: ###-####. ok to cover walls only 2nd floor except barrell area, 1st floor E1/2 except assembly area and baths. 1/5/2005 12:58:54 PM
|
ELE04-03800
| Final | 1/5/2005 | 1/5/2005 | 1/5/2005 12:00:00 AM | P | PASS |
|
|
Brent; Phone #: ###-#### Internet Inspection Request from: Jan Rice called contr for seismic wires for 3 fixtures. ok to final 1/5/2005 1:55:24 PM
|
ELE04-02500
| Final | 1/5/2005 | 1/5/2005 | 1/5/2005 12:00:00 AM | P | PASS |
|
|
Terry; Phone #: ###-#### Internet Inspection Request from: Jan Rice corrections made. ok to final. 1/5/2005 4:48:47 PM
|