GCE15-00001
| GCE-Permanent Service | 1/5/2015 | 1/5/2015 | 1/5/2015 3:44:28 PM | P | FAIL |
|
|
Corey ###-#### 110.12(B) Integrity of Electrical Equipment and Connections. Internal parts of electrical equipment, including busbars, wiring terminals, insulators, and other surfaces, shall not be damaged or contaminated by foreign materials. 250.53- Unable to verify grounding electrode system. 2 rods required for permenant service. *Unable to verify rating of cord from moble home to service
|
ELE14-03119
| Final | 12/31/2014 | 1/5/2015 | 1/5/2015 2:59:04 PM | P | PASS |
|
|
Kenny Phone #: ###-#### Final ok
|
ELE14-03242
| Electrical Rough-In | 1/5/2015 | 1/5/2015 | 1/5/2015 2:28:14 PM | P | PASS |
|
|
Partial wall inspection. Call contact before inspection please. Thank you Phone #: ###-#### Inspection requested via web by Chris Chesnut Walls in lobby area rough in ok cover
|
ELE14-03364
| Final | 1/5/2015 | 1/5/2015 | 1/5/2015 1:49:24 PM | P | FAIL |
|
|
Final inspection for this property. Contact is Justin Metcalf. Thank you and have a good day. Phone #: ###-#### Inspection requested via web by Laura Longshaw 210.8-Ground fault circuit interupters shall be installed in a readily accessible location. 210.8(B)(5)- Receptical outlets located with in 6' of sink shall have GFCI protection. 400.8- Flexible cordd shall not be ran through holes in walls. BCC 4-05-32 Code violations not to be retained 314.29- Boxes shall be installed so that the wiring contained in them can be rendered accessible without removing any part of building.
|
MIS14-00290
| ELE-Conference | 1/5/2015 | 1/5/2015 | 1/5/2015 9:46:21 AM | P | CANC |
|
|
Check for permit for interior of enclosed porch
|
MIS14-00290
| ELE-Conference | 12/16/2014 | 1/5/2015 | 1/5/2015 9:42:31 AM | A | NH |
|
|
Check for permit for interior work Unable to make contact. no answer at door
|
ELE14-03042
| Final | 1/5/2015 | 1/5/2015 | 1/5/2015 9:27:12 AM | A | PASS |
|
|
call first ###-#### Phone #: ###-#### Inspection requested via web by PAT MILLER Final ok
|
ELE14-03042
| Electrical Rough-In | 1/5/2015 | 1/5/2015 | 1/5/2015 9:26:45 AM | A | PASS |
|
|
call first ###-#### Phone #: ###-#### Inspection requested via web by PAT MILLER Mini split rough in ok
|
ELE14-03562
| Final | 12/31/2014 | 1/5/2015 | 1/5/2015 9:00:32 AM | A | PASS |
|
|
Shannon is the contact his cell no. is ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates Final ok
|
ELE14-03562
| Electrical Rough-In | 1/5/2015 | 1/5/2015 | 1/5/2015 9:00:02 AM | P | PASS |
|
|
Shannon is the contact his cell no. is ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates Work station recepticals rough in ok
|