Inspections for the day of: Tuesday, January 5, 2016.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Little
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM15-04144 Final1/5/20161/5/20161/5/2016 3:20:36 PMPPASS
Phone #: ###-#### Inspection requested via web by Jason Gonzalez
PLM15-04396 Plumbing Rough-in1/4/20161/5/20161/5/2016 2:57:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Branden Steers
>why use red and blue pipe if your gonna run red to everything that should have blue?
PLM15-04395 Plumbing Rough-in1/4/20161/5/20161/5/2016 2:50:40 PMPPASS
Phone #: ###-#### Inspection requested via web by Branden Steers
PLM15-04353 Plumbing Rough-in1/5/20161/5/20161/5/2016 2:24:02 PMPFAIL
Phone #: ###-#### Inspection requested via web by Aarin Van Curen
1>mising nail plates everywhere.
2>3" trap arm on water closet backgraded and must be run at no more than 1/4" per foot.
3>deck drain needs to have a flange to provide for water tight seal 411.1 ISPC
4>all holes for vent penetrations need to be drilled through roof at time of inspection.
PLM15-04358 Plumbing Rough-in1/5/20161/5/20161/5/2016 2:19:56 PMPFAIL
Phone #: ###-#### Inspection requested via web by Aarin Van Curen
1>missing nail plates
2>vent from hub drain must terminate from edge of open window.
3>flat or backgraded vent on water closet over kitchen.
PLM15-02609 PLM-Aging Inspection1/5/20161/5/20161/5/2016 10:14:49 AM PART
wip
PLM15-04341 Plumbing Rough-in1/4/20161/5/20161/5/2016 9:56:15 AMAFAIL
Jacob Phone #: ###-####
>leak at tub shoe, fix and retest and re inspect.
>water ok
PLM15-00618 Plumbing Rough-in1/5/20161/5/20161/5/2016 9:28:02 AMAPASS
Phone #: ###-#### Inspection requested via web by Michael Webb
PLM15-02521 PLM-Aging Inspection1/5/20161/5/20161/5/2016 9:15:27 AM PART
wip
PLM15-04353 Water and/or Sewer1/5/20161/5/20161/5/2016 7:47:29 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Aarin Van Curen Inspection cancelled from web by: Aarin Van Curen
PLM15-04201 Final1/4/20161/5/20161/4/2016 3:28:32 PMAPASS
Tim-Tim thought permit should be finaled-could you check and if permit is ready could you final? Phone #: ###-####
>rough done same time as gw.