Inspections for the day of: Tuesday, January 7, 2020.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-03220 Final1/7/20201/7/20201/7/2020 3:11:50 PMPPASS
Bulk N2O system building. Phone #: ###-#### Inspection requested via web by Steve Moss Final ok
ELE20-00062 Final1/6/20201/7/20201/7/2020 1:43:50 PMPPASS
New 40A 240V circuit from panel in garage to AC disconnect. Extended existing 20A 120V circuit for service receptacle. Call Wyatt for details. Thanks. Phone #: ###-#### Inspection requested via web by Dan Hilke Final ok
ELE20-00062 Electrical Rough-In1/7/20201/7/20201/7/2020 1:10:55 PMPPASS
New 40A 240V circuit from panel in garage to AC disconnect. Extended existing 20A 120V circuit for service receptacle. Call Wyatt for details. Thanks. Phone #: ###-#### Inspection requested via web by Dan Hilke Rough in ok
ELE19-04487 Electrical Rough-In1/7/20201/7/20201/7/2020 1:10:18 PMPPASS
May have messed up crew called the historical for inspection forgot to online request. Crew is in area to go remove panels Phone #: ###-#### Inspection requested via web by Ashley Rasmussen Listing only ok. (Discussed conduit to detached garage being used for 240V 30A welder cuircuit. Disc. will be required. also discussed loose EMT connectors) Breaker labeling must be completed before final. Listing ok only
ELE19-04067 Final1/7/20201/7/20201/7/2020 12:22:42 PMPFAIL
Garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk 314.20 Dining room bar receps shall have spark rings. 314.23 Boxes shall be securely fastened.(Fireplace recep) 110.3B Equipment shall be installed per man specs.( Down Bath and up bed vanity receps Dead. Up master bath fan Dead)
ELE19-04433 Temporary Service1/6/20201/7/20201/7/2020 10:56:19 AMAPASS
Phone #: ###-#### Inspection requested via web by Troy Ballard t/s u/g n ok
ELE20-00054 Temporary Service1/6/20201/7/20201/7/2020 10:55:15 AMAPASS
Phone #: ###-#### Inspection requested via web by Troy Ballard t/s u/g n ok
ELE20-00055 Temporary Service1/6/20201/7/20201/7/2020 10:53:58 AMAPASS
Phone #: ###-#### Inspection requested via web by Troy Ballard t/s u/g n ok
ELE19-04822 Final1/6/20201/7/20201/7/2020 8:49:35 AMAFAIL
corrections made..thanks! Phone #: ###-#### Inspection requested via web by Richard Gratiot Upon re-inspect, additional wire had been installed in the garage. 12-2 romex hanging above panel, wire running through attic access, 2 Single gang boxes installed at front of garage have not been trimmed out.
ELE17-02229 ELE-Aging Inspection1/7/20201/7/20201/7/2020 7:10:31 AM DONE
Corrections not made Waiting on contractor to schedule final.
ELE17-02227 ELE-Aging Inspection1/7/20201/7/20201/7/2020 7:08:56 AM DONE
No activity other than aging inspections. Waiting on cantractor to schedule with owner.