ELE19-03220
| Final | 1/7/2020 | 1/7/2020 | 1/7/2020 3:11:50 PM | P | PASS |
|
|
Bulk N2O system building. Phone #: ###-#### Inspection requested via web by Steve Moss Final ok
|
ELE20-00062
| Final | 1/6/2020 | 1/7/2020 | 1/7/2020 1:43:50 PM | P | PASS |
|
|
New 40A 240V circuit from panel in garage to AC disconnect. Extended existing 20A 120V circuit for service receptacle. Call Wyatt for details. Thanks. Phone #: ###-#### Inspection requested via web by Dan Hilke Final ok
|
ELE20-00062
| Electrical Rough-In | 1/7/2020 | 1/7/2020 | 1/7/2020 1:10:55 PM | P | PASS |
|
|
New 40A 240V circuit from panel in garage to AC disconnect. Extended existing 20A 120V circuit for service receptacle. Call Wyatt for details. Thanks. Phone #: ###-#### Inspection requested via web by Dan Hilke Rough in ok
|
ELE19-04487
| Electrical Rough-In | 1/7/2020 | 1/7/2020 | 1/7/2020 1:10:18 PM | P | PASS |
|
|
May have messed up crew called the historical for inspection forgot to online request. Crew is in area to go remove panels Phone #: ###-#### Inspection requested via web by Ashley Rasmussen Listing only ok. (Discussed conduit to detached garage being used for 240V 30A welder cuircuit. Disc. will be required. also discussed loose EMT connectors) Breaker labeling must be completed before final. Listing ok only
|
ELE19-04067
| Final | 1/7/2020 | 1/7/2020 | 1/7/2020 12:22:42 PM | P | FAIL |
|
|
Garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk 314.20 Dining room bar receps shall have spark rings. 314.23 Boxes shall be securely fastened.(Fireplace recep) 110.3B Equipment shall be installed per man specs.( Down Bath and up bed vanity receps Dead. Up master bath fan Dead)
|
ELE19-04433
| Temporary Service | 1/6/2020 | 1/7/2020 | 1/7/2020 10:56:19 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Troy Ballard t/s u/g n ok
|
ELE20-00054
| Temporary Service | 1/6/2020 | 1/7/2020 | 1/7/2020 10:55:15 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Troy Ballard t/s u/g n ok
|
ELE20-00055
| Temporary Service | 1/6/2020 | 1/7/2020 | 1/7/2020 10:53:58 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Troy Ballard t/s u/g n ok
|
ELE19-04822
| Final | 1/6/2020 | 1/7/2020 | 1/7/2020 8:49:35 AM | A | FAIL |
|
|
corrections made..thanks! Phone #: ###-#### Inspection requested via web by Richard Gratiot Upon re-inspect, additional wire had been installed in the garage. 12-2 romex hanging above panel, wire running through attic access, 2 Single gang boxes installed at front of garage have not been trimmed out.
|
ELE17-02229
| ELE-Aging Inspection | 1/7/2020 | 1/7/2020 | 1/7/2020 7:10:31 AM | | DONE |
|
|
Corrections not made Waiting on contractor to schedule final.
|
ELE17-02227
| ELE-Aging Inspection | 1/7/2020 | 1/7/2020 | 1/7/2020 7:08:56 AM | | DONE |
|
|
No activity other than aging inspections. Waiting on cantractor to schedule with owner.
|