Inspections for the day of: Monday, January 8, 2018.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM17-03463 Final1/8/20181/8/20181/8/2018 4:54:32 PMPPASS
Can you call Bryan with Lexar Homes please he can be there in 15 min.
Thanks
Sem Phone #: ###-#### Inspection requested via web by Semsudin Konjuhovac
PLM18-00050 Final1/4/20181/8/20181/8/2018 4:21:52 PMPPASS
Please call homeowner 30 minutes in advance for access at ###-#### and call Eddie with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Lea Briggs
PLM17-03716 Plumbing Rough-in1/8/20181/8/20181/8/2018 4:04:52 PMPFAIL
Mike Phone #: ###-####.
Santees cannot be installed on their back. Install wye branch fittings on the horizontal.
PLM17-04533 Final1/4/20181/8/20181/8/2018 3:22:40 PMPFAIL
Lock box code 0726 Phone #: ###-#### Inspection requested via web by Ryan Baker.
1. The dishwasher drain must rise to the highest point in the cabinet.
2.. Only one slip-joint is allowed on the outlet side of the weir.
3. Pipe the water heater t&p outside of the closure.
4. Each flue joint on the water heater must have 3 screws.
5. Add a 3" drip leg to the water heater gas feed.
PLM18-00078 Plumbing Rough-in1/8/20181/8/20181/8/2018 2:59:52 PMPPART
Phone #: ###-#### Inspection requested via web by Raul Castanon
1. the water softener drain must be 3/4
2. Add a 3" cleanout above the floor for the powder bath.
3. Add a cleanout to the back to back lavatories at the pool bath.
PLM17-04374 DOC - Permit Finaled1/8/20181/8/20181/8/2018 2:32:04 PMPPASS
PLM16-04144 Final1/8/20181/8/20181/8/2018 2:28:36 PMPPART
Bldg 300 complete with the expecption of the corroction notice to add a rp to the dishwasher.
PLM17-01748 Final1/5/20181/8/20181/8/2018 9:32:56 AMAFAIL
Key in electrical outlet west wall Phone #: ###-#### Inspection requested via web by Jeff Coate.
Pex cannot be within 18" of the water heater on the hot and cold connections. Use copper.

Trap seal exceeds 4".
Look at a LA pattern trap with a trap adapter.
The sink will adjust up at the bottom of the legs.
PLM17-05070 Water and/or Sewer1/5/20181/8/20181/8/2018 9:14:39 AMAPART
PLEASE INSPECT THE WATER LINE ONLY Phone #: ###-#### Inspection requested via web by Darren Wood.
Water service ok to cover
PLM17-04815 Water and/or Sewer1/5/20181/8/20181/8/2018 8:56:24 AMAPART
Please accommodate an 8 o''clock inspection Phone #: ###-#### Inspection requested via web by David Scaggs.
Water service ok to cover