MEC19-00092
| Rough-in | 1/8/2019 | 1/8/2019 | 1/9/2019 6:21:30 AM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Joe Taylor need flue pressure test, need approved manual j Manual J doesnt match house layout. cannot have supply duct in a exterior wall its not insulated and doesnt mantain building insulation envulop.
|
MEC18-04549
| Final | 1/8/2019 | 1/8/2019 | 1/8/2019 3:35:35 PM | P | PASS |
|
|
field super: Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC19-00092
| Pressure Test | 1/8/2019 | 1/8/2019 | 1/8/2019 2:45:48 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Joe Taylor 20lb gas
|
MEC18-00631
| Rough-in | 1/8/2019 | 1/8/2019 | 1/8/2019 2:28:09 PM | P | PASS |
|
|
above ceiling condensate piping, if questions call Glen @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann all condensate complete
|
MEC18-02329
| Final | 1/7/2019 | 1/8/2019 | 1/8/2019 2:04:50 PM | P | PASS |
|
|
MARLA ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
|
MEC18-05278
| Rough-in | 1/8/2019 | 1/8/2019 | 1/8/2019 1:37:14 PM | P | PASS |
|
|
LOCK BOX 7565 Phone #: ###-#### Inspection requested via web by Aaron Alandt
|
MEC18-05278
| Final | 1/8/2019 | 1/8/2019 | 1/8/2019 1:37:05 PM | P | PASS |
|
|
LOCK BOX 7565 Phone #: ###-#### Inspection requested via web by Aaron Alandt
|
MEC18-04902
| Final | 1/8/2019 | 1/8/2019 | 1/8/2019 11:54:48 AM | A | PASS |
|
|
Inspection requested via web by JOSE DUARTE
|
MEC18-02897
| Final | 1/2/2019 | 1/8/2019 | 1/8/2019 11:14:33 AM | A | FAIL |
|
|
###-#### please call when you are on the way either number is good Phone #: ###-#### Inspection requested via web by Marisa Hone need to witness flue pressure tests, not enough combustion air, each furnace needs its own disconnect
|
MEC18-00350
| Conference | 1/3/2019 | 1/8/2019 | 1/8/2019 10:45:47 AM | A | PASS |
|
|
CM company is asking for a inspection conference at 10:00 am on Boise High School jobsite for next Tuesday the 8th of January. He has all of the trades calling in to have all inspectors walk the jobsite to list what they will need to get TCO, BY the 11th of January. Contact Steve ###-#### Phone #: ###-#### Inspection requested via web by Dan Flaherty
|
MEC18-00350
| Rough-in | 1/8/2019 | 1/8/2019 | 1/8/2019 10:45:35 AM | P | PASS |
|
|
area B basement above grid okay
|
MEC18-04600
| Final | 1/7/2019 | 1/8/2019 | 1/8/2019 9:54:13 AM | A | PASS |
|
|
Duct Blast witness @ 10AM Phone #: ###-#### Inspection requested via web by Gary Reeves blast test okay
|
MEC18-05930
| Final | 1/4/2019 | 1/8/2019 | 1/8/2019 9:45:17 AM | A | FAIL |
|
|
Please call James O''Hara prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette need combustion air from outdoors, need to gasket the door to furnace
|
MEC19-00005
| Final | 1/7/2019 | 1/8/2019 | 1/8/2019 8:38:34 AM | A | PASS |
|
|
Our final was pending an electrical permit. Electrical permit has passed. Phone #: ###-#### Inspection requested via web by Arielle Hendricks
|
MEC18-04977
| Final | 1/7/2019 | 1/8/2019 | 1/8/2019 8:38:04 AM | A | PASS |
|
|
lock box behind fake plant on front porch code is 1987 - - 26ga steel 90 is penetrating sheetrock at garage/attic level up into attic space. Flex duct is connected to steel elbow above sheetrock in attic space. Outer liner of flex duct in attic is pulled down below sheetrock covering 26ga steel duct in garage for insulation value. Phone #: ###-#### Inspection requested via web by Dave Sorensen
|
MEC17-04675
| Mec-Aging Inspection | 1/8/2019 | 1/8/2019 | 1/8/2019 8:05:18 AM | | CANC |
|
|
|