MEC19-02333
| Final | 1/8/2020 | 1/8/2020 | 1/8/2020 3:57:39 PM | P | PASS |
|
|
Please call megan on your way there Megan said she makes it home between 3:45 and 4pm from work. Thanks Phone #: ###-#### Inspection requested via web by Manuel Canto - final ok
|
MEC20-00058
| Rough-in | 1/8/2020 | 1/8/2020 | 1/8/2020 3:48:50 PM | P | FAIL |
|
|
Duct wrap Francisco is the contact. Phone #: ###-#### Inspection requested via web by Scott Corriea - duct seal needs finished
|
MEC20-00036
| Final | 1/8/2020 | 1/8/2020 | 1/8/2020 3:01:39 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Nick Drake - 5lb flue pressure test fail
|
MEC20-00089
| Final | 1/8/2020 | 1/8/2020 | 1/8/2020 3:01:13 PM | P | PASS |
|
|
Laura ; Mark Aguinaga ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace ac coil co ok
|
MEC19-05047
| Final | 1/7/2020 | 1/8/2020 | 1/8/2020 2:40:04 PM | P | NH |
|
|
Phone #: ###-#### Inspection requested via web by James Cox - no access to home talked with contractor via phone call
|
MEC20-00094
| Final | 1/7/2020 | 1/8/2020 | 1/8/2020 2:39:13 PM | P | FAIL |
|
|
Please call Dave on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - furnace pvc flue needs clearances to single wall water heater flue or changed out to b vent
|
MEC20-00018
| Final | 1/3/2020 | 1/8/2020 | 1/8/2020 1:57:01 PM | P | PASS |
|
|
Homeowner Teresa McGill ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace ac coil co ok
|
MEC19-05601
| Final | 1/6/2020 | 1/8/2020 | 1/8/2020 1:38:14 PM | P | CANC |
|
|
installer david ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - should have been a R/I inspection - need city approved prints onsite
|
MEC19-05601
| Rough-in | 1/8/2020 | 1/8/2020 | 1/8/2020 1:37:41 PM | P | FAIL |
|
|
installer david ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - need city approved prints onsite before R/I cover - will need to see TAB report for final
|
MEC20-00038
| Final | 1/6/2020 | 1/8/2020 | 1/8/2020 1:19:31 PM | P | FAIL |
|
|
Please inspect from 2-3 and call Paul prior to inspection. ###-####. Phone #: ###-#### Inspection requested via web by Mary LaFayette - combustible material is touching b vent flue in crawl - flue needs to maintain 1" clearances through out
|
MEC20-00101
| Rough-in | 1/8/2020 | 1/8/2020 | 1/8/2020 11:54:09 AM | P | CANC |
|
|
unit heater, BBQ and Ductless system Phone #: ###-#### >> Inspection requested via web by SOPHIA FLEMING Inspection cancelled from web by: SOPHIA FLEMING
|
MEC19-04795
| Final | 1/7/2020 | 1/8/2020 | 1/8/2020 11:00:29 AM | A | PASS |
|
|
The garage code for entry is 1400 enter. Thank you. Phone #: ###-#### Inspection requested via web by claude croy - final ok
|
MEC20-00032
| Rough-in | 1/7/2020 | 1/8/2020 | 1/8/2020 10:35:08 AM | A | PASS |
|
|
Mary Phone #: ###-#### - range venting R/I ok
|
MEC19-03096
| Conference | 1/7/2020 | 1/8/2020 | 1/8/2020 10:25:23 AM | A | PASS |
|
|
Please call Bryan at least 30 min prior to inspection, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum
|
MEC19-03096
| Rough-in | 1/8/2020 | 1/8/2020 | 1/8/2020 10:24:59 AM | A | PART |
|
|
Please call Bryan at least 30 min prior to inspection, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum 2- 8" F/S damper clearances ok all bathroom hard lids ok for cover other than two guest bathrooms in the corridor next to gym. - talked with HVAC contractor and general about fire dampers in ceiling/floor assembly per approved drawnings. Contractor says they will not be able to fit a fire damper in ceiling space. Explained that they will need to have this issue looked at by design professional and then reviewed by city before moving foward.
|
MEC19-04324
| Final | 1/7/2020 | 1/8/2020 | 1/8/2020 9:21:56 AM | A | FAIL |
|
|
Santiago Phone #: ###-#### - need access to roof to inspect outdoor unit and venting - condensate needs to be per the approved prints/min 3/4 pvc - return and supply ducting is not per approved prints. return missing duct/supply duct is missing all dampers including fresh air duct. - electric heater in bathroom is missing
|
MEC20-00076
| Final | 1/8/2020 | 1/8/2020 | 1/8/2020 9:14:11 AM | A | FAIL |
|
|
Call homeowner 30 min before Thanks Phone #: ###-#### Inspection requested via web by Manuel Canto - water heater connector vent needs to enter common vent at highest point in wye. switch furnace and water heater connection point to wye
|
MEC19-02524
| Mec-Aging Inspection | 1/8/2020 | 1/8/2020 | 1/8/2020 9:09:27 AM | | FAIL |
|
|
Permit has not been active since being issued on 6-14-19. Schedule inspection with owners if work is finished. Permit will expired at next mechanical aging inspection if not active.
|
MEC19-02653
| Mec-Aging Inspection | 1/8/2020 | 1/8/2020 | 1/8/2020 9:09:04 AM | | FAIL |
|
|
Permit has not been active since being issued on 6-20-19. Schedule inspection with owners if work is finished. Permit will expired at next mechanical aging inspection if not active.
|