Inspections for the day of: Wednesday, January 8, 2020.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-02333 Final1/8/20201/8/20201/8/2020 3:57:39 PMPPASS
Please call megan on your way there
Megan said she makes it home between
3:45 and 4pm from work.
Thanks
Phone #: ###-#### Inspection requested via web by Manuel Canto
- final ok
MEC20-00058 Rough-in1/8/20201/8/20201/8/2020 3:48:50 PMPFAIL
Duct wrap Francisco is the contact. Phone #: ###-#### Inspection requested via web by Scott Corriea
- duct seal needs finished
MEC20-00036 Final1/8/20201/8/20201/8/2020 3:01:39 PMPFAIL
Phone #: ###-#### Inspection requested via web by Nick Drake
- 5lb flue pressure test fail
MEC20-00089 Final1/8/20201/8/20201/8/2020 3:01:13 PMPPASS
Laura ; Mark Aguinaga ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace ac coil co ok
MEC19-05047 Final1/7/20201/8/20201/8/2020 2:40:04 PMPNH
Phone #: ###-#### Inspection requested via web by James Cox
- no access to home talked with contractor via phone call
MEC20-00094 Final1/7/20201/8/20201/8/2020 2:39:13 PMPFAIL
Please call Dave on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- furnace pvc flue needs clearances to single wall water heater flue or changed out to b vent
MEC20-00018 Final1/3/20201/8/20201/8/2020 1:57:01 PMPPASS
Homeowner Teresa McGill ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace ac coil co ok
MEC19-05601 Final1/6/20201/8/20201/8/2020 1:38:14 PMPCANC
installer david ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- should have been a R/I inspection
- need city approved prints onsite
MEC19-05601 Rough-in1/8/20201/8/20201/8/2020 1:37:41 PMPFAIL
installer david ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- need city approved prints onsite before R/I cover
- will need to see TAB report for final
MEC20-00038 Final1/6/20201/8/20201/8/2020 1:19:31 PMPFAIL
Please inspect from 2-3 and call Paul prior to inspection. ###-####. Phone #: ###-#### Inspection requested via web by Mary LaFayette
- combustible material is touching b vent flue in crawl
- flue needs to maintain 1" clearances through out
MEC20-00101 Rough-in1/8/20201/8/20201/8/2020 11:54:09 AMPCANC
unit heater, BBQ and Ductless system Phone #: ###-#### >> Inspection requested via web by SOPHIA FLEMING Inspection cancelled from web by: SOPHIA FLEMING
MEC19-04795 Final1/7/20201/8/20201/8/2020 11:00:29 AMAPASS
The garage code for entry is 1400 enter.
Thank you. Phone #: ###-#### Inspection requested via web by claude croy
- final ok
MEC20-00032 Rough-in1/7/20201/8/20201/8/2020 10:35:08 AMAPASS
Mary Phone #: ###-####
- range venting R/I ok
MEC19-03096 Conference1/7/20201/8/20201/8/2020 10:25:23 AMAPASS
Please call Bryan at least 30 min prior to inspection, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum
MEC19-03096 Rough-in1/8/20201/8/20201/8/2020 10:24:59 AMAPART
Please call Bryan at least 30 min prior to inspection, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum
2- 8" F/S damper clearances ok
all bathroom hard lids ok for cover other than two guest bathrooms in the corridor next to gym.
- talked with HVAC contractor and general about fire dampers in ceiling/floor assembly per approved drawnings. Contractor says they will not be able to fit a fire damper in ceiling space. Explained that they will need to have this issue looked at by design professional and then reviewed by city before moving foward.
MEC19-04324 Final1/7/20201/8/20201/8/2020 9:21:56 AMAFAIL
Santiago Phone #: ###-####
- need access to roof to inspect outdoor unit and venting
- condensate needs to be per the approved prints/min 3/4 pvc
- return and supply ducting is not per approved prints. return missing duct/supply duct is missing all dampers including fresh air duct.
- electric heater in bathroom is missing
MEC20-00076 Final1/8/20201/8/20201/8/2020 9:14:11 AMAFAIL
Call homeowner 30 min before
Thanks Phone #: ###-#### Inspection requested via web by Manuel Canto
- water heater connector vent needs to enter common vent at highest point in wye. switch furnace and water heater connection point to wye
MEC19-02524 Mec-Aging Inspection1/8/20201/8/20201/8/2020 9:09:27 AM FAIL
Permit has not been active since being issued on 6-14-19. Schedule inspection with owners if work is finished. Permit will expired at next mechanical aging inspection if not active.
MEC19-02653 Mec-Aging Inspection1/8/20201/8/20201/8/2020 9:09:04 AM FAIL
Permit has not been active since being issued on 6-20-19. Schedule inspection with owners if work is finished. Permit will expired at next mechanical aging inspection if not active.