PLM07-03542
| Roof Drains | 1/9/2008 | 1/9/2008 | 1/9/2008 4:48:09 PM | P | PART |
|
|
backgraded 4" roof drain on east side pass. will final permit when revised site plans are received & excepted by lee rice & eric strole.
|
PLM08-00052
| Water Softner Final | 1/9/2008 | 1/9/2008 | 1/9/2008 4:00:29 PM | P | PASS |
|
|
|
PLM07-04137
| Plumbing Rough-in | 1/9/2008 | 1/9/2008 | 1/9/2008 3:48:32 PM | P | FAIL |
|
|
dwv & water test failed in both sides.
|
PLM08-00050
| Plumbing Rough-in | 1/9/2008 | 1/9/2008 | 1/9/2008 3:47:14 PM | P | FAIL |
|
|
bob Phone #: ###-####-pipe island sink per 2003 upc, need c/o on foot vent, need c/o on base of stack, water lines for future bath need to be relocated as not subject to freezeing, need 90 on trap arm for future toilet.
|
PLM08-00030
| Water Heater Final | 1/9/2008 | 1/9/2008 | 1/9/2008 1:51:08 PM | P | PASS |
|
|
please call Kelea with questions at ###-####. thanks! Phone #: ###-#### Internet Inspection Request from: Kelea Dunne
|
PLM08-00052
| Final | 1/8/2008 | 1/9/2008 | 1/9/2008 10:20:33 AM | A | FAIL |
|
|
please call Barbara Kuchenriter the owner before going out to make sure home. # ###-#### -need shut off valve for water softner. THANK YOU Phone #: ###-#### Internet Inspection Request from: Jon VanVleet
|
PLM07-02470
| Plumbing Rough-in | 1/9/2008 | 1/9/2008 | 1/9/2008 10:19:19 AM | A | PART |
|
|
reinspection-all corrections that are not covered with sheetrock are complete, what is covered can be checked on final test, need to retest water & tie in 4" roof drain in building & test & finish wrap on w-3.
|
PLM07-04137
| Plumbing Rough-in | 1/7/2008 | 1/9/2008 | 1/9/2008 8:58:16 AM | A | FAIL |
|
|
boris Phone #: ###-####-dwv & water test failed (both sides)
|