Inspections for the day of: Monday, January 9, 2012.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02527 Final1/9/20121/9/20121/9/2012 3:04:56 PMPPASS
code is 7530 Phone #: ###-#### >> Inspection requested via web by Darryn Coburn ok final
ELE12-00036 Final1/9/20121/9/20121/9/2012 1:48:46 PMPPASS
call corey with questions Phone #: ###-#### >> Inspection requested via web by Don Lustig ok final, signed card
ELE11-02296 Final1/9/20121/9/20121/9/2012 1:00:10 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman called, left correction notice, NEC 250.94 shall provide intersystem ground bar, 110.12(B) shall provide gfci that is not broken, 210.8(A)(3) shall provide gfci protection for outdoor receptacles, 406.4 all receptacles shall be securely mounted, 352.30 shall strap riser
ELE11-02715 Final1/6/20121/9/20121/9/2012 10:22:07 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Tyler Bowen ok final, no card
ELE09-01934 ELE-Aging Inspection1/9/20121/9/20121/9/2012 9:15:29 AM DONE
called owner, no electrical will be done, see final
ELE09-01934 Final1/9/20121/9/20121/9/2012 9:15:12 AMAPASS
per call to owner, no electrical will be done, ok final
ELE12-00041 Electrical Rough-In1/6/20121/9/20121/9/2012 9:12:57 AMAPASS
Under ground Phone #: ###-#### >> Inspection requested via web by TOM BICANDI u/g house to garage only ok
ELE12-00040 Electrical Rough-In1/6/20121/9/20121/9/2012 9:05:35 AMAPASS
Under ground Phone #: ###-#### >> Inspection requested via web by TOM BICANDI u/g house to garage only ok
ELE12-00039 Electrical Rough-In1/6/20121/9/20121/9/2012 8:43:32 AMAPASS
Under ground Phone #: ###-#### >> Inspection requested via web by TOM BICANDI u/g house to garage only ok
ELE12-00038 Electrical Rough-In1/6/20121/9/20121/9/2012 8:05:34 AMAPASS
Under ground Phone #: ###-#### >> Inspection requested via web by TOM BICANDI u/g house to garage only ok