Inspections for the day of: Friday, January 9, 2015.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-03166 Permanent Service1/9/20151/9/20151/9/2015 2:55:53 PMPPASS
Phone #: ###-#### Inspection requested via web by Celinda Winters p/s u/g n ok
ELE14-03473 Final1/9/20151/9/20151/9/2015 2:23:08 PMPNR
We are eliminating panel in closet and addinf all in one service on rear of house.If possible would like to have inspection late to insure enough time to complete project. Thanks Phone #: ###-#### Inspection requested via web by jason shifflett Will call in when labels complete.
ELE14-03473 Permanent Service1/9/20151/9/20151/9/2015 2:22:46 PMPPASS
We are eliminating panel in closet and addinf all in one service on rear of house.If possible would like to have inspection late to insure enough time to complete project. Thanks Phone #: ###-#### Inspection requested via web by jason shifflett p/s o/h n ok
ELE14-03498 Conference1/9/20151/9/20151/9/2015 1:50:23 PMPDONE
Mark-please call to meet Phone #: ###-#### Discussed small remodel of main hall bathroom. Required dedicated, GFCI protected 20 amp circuit for receptacle. Wire to be fished down existing wall so owner will not call for rough in just final inspection.
ELE15-00060 Electrical Rough-In1/9/20151/9/20151/9/2015 1:24:54 PMPPASS
call Brian for access info Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Demising wall rough in ok cover
ELE14-03092 Final1/8/20151/9/20151/9/2015 12:24:32 PMPPASS
Installed 1 wall sign reading Telco. ALL PRIMARY POWER BY OTHERS Phone #: ###-#### Inspection requested via web by Ken Olsen Disconnecting means and UL listing confirmed. Final ok
ELE14-03021 Final1/8/20151/9/20151/9/2015 12:06:33 PMAPASS
Phone #: ###-#### Inspection requested via web by Laurie Hoelscher Disconnecting means and UL listing confirmed. Final ok
ELE14-03021 Electrical Rough-In1/9/20151/9/20151/9/2015 12:06:20 PMPPASS
Phone #: ###-#### Inspection requested via web by Laurie Hoelscher Sign rough in ok
ELE14-03319 Final1/8/20151/9/20151/9/2015 11:47:39 AMAPASS
Tom Phone #: ###-#### Final ok
ELE14-02582 Final1/8/20151/9/20151/9/2015 11:03:10 AMAPASS
james is the contact at ###-#### Phone #: ###-#### Inspection requested via web by Tracy Robertson No card posted office locked Final ok
ELE14-00698 Final1/8/20151/9/20151/9/2015 10:25:40 AMAFAIL
The code for door is AHC for lock box on back door. Home is vacant Phone #: ###-#### Inspection requested via web by Randy Fletcher 240.24(D)- Overcurrent devices shall not be located in the vicinity of easily ignitible material, such as clothes closets.
240.4- Max overcurrent for protection of conductors- 14 ga 15 amp max, 10 ga 30 amp max.
210.4(D)- Check multi-wire branch circuits for proper phasing to ensure grounded conductor does not carry current from both legs.
*New wire dated 2013 in panel for furnace and master bath not on permit.
210.52- Receptacle outlet spacing in master bed and kitchen counter top areas does not comply with 210.52.
*Record of 2 notices given to pull permits for remodel work, MIS14-00273, MIS14-00314.
ELE14-02834 Final1/8/20151/9/20151/9/2015 8:33:53 AMAPASS
Phone #: ###-#### Inspection requested via web by Laurie Hoelscher Sign listing confirmed. Final ok