ELE14-03166
| Permanent Service | 1/9/2015 | 1/9/2015 | 1/9/2015 2:55:53 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Celinda Winters p/s u/g n ok
|
ELE14-03473
| Final | 1/9/2015 | 1/9/2015 | 1/9/2015 2:23:08 PM | P | NR |
|
|
We are eliminating panel in closet and addinf all in one service on rear of house.If possible would like to have inspection late to insure enough time to complete project. Thanks Phone #: ###-#### Inspection requested via web by jason shifflett Will call in when labels complete.
|
ELE14-03473
| Permanent Service | 1/9/2015 | 1/9/2015 | 1/9/2015 2:22:46 PM | P | PASS |
|
|
We are eliminating panel in closet and addinf all in one service on rear of house.If possible would like to have inspection late to insure enough time to complete project. Thanks Phone #: ###-#### Inspection requested via web by jason shifflett p/s o/h n ok
|
ELE14-03498
| Conference | 1/9/2015 | 1/9/2015 | 1/9/2015 1:50:23 PM | P | DONE |
|
|
Mark-please call to meet Phone #: ###-#### Discussed small remodel of main hall bathroom. Required dedicated, GFCI protected 20 amp circuit for receptacle. Wire to be fished down existing wall so owner will not call for rough in just final inspection.
|
ELE15-00060
| Electrical Rough-In | 1/9/2015 | 1/9/2015 | 1/9/2015 1:24:54 PM | P | PASS |
|
|
call Brian for access info Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Demising wall rough in ok cover
|
ELE14-03092
| Final | 1/8/2015 | 1/9/2015 | 1/9/2015 12:24:32 PM | P | PASS |
|
|
Installed 1 wall sign reading Telco. ALL PRIMARY POWER BY OTHERS Phone #: ###-#### Inspection requested via web by Ken Olsen Disconnecting means and UL listing confirmed. Final ok
|
ELE14-03021
| Final | 1/8/2015 | 1/9/2015 | 1/9/2015 12:06:33 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Laurie Hoelscher Disconnecting means and UL listing confirmed. Final ok
|
ELE14-03021
| Electrical Rough-In | 1/9/2015 | 1/9/2015 | 1/9/2015 12:06:20 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Laurie Hoelscher Sign rough in ok
|
ELE14-03319
| Final | 1/8/2015 | 1/9/2015 | 1/9/2015 11:47:39 AM | A | PASS |
|
|
Tom Phone #: ###-#### Final ok
|
ELE14-02582
| Final | 1/8/2015 | 1/9/2015 | 1/9/2015 11:03:10 AM | A | PASS |
|
|
james is the contact at ###-#### Phone #: ###-#### Inspection requested via web by Tracy Robertson No card posted office locked Final ok
|
ELE14-00698
| Final | 1/8/2015 | 1/9/2015 | 1/9/2015 10:25:40 AM | A | FAIL |
|
|
The code for door is AHC for lock box on back door. Home is vacant Phone #: ###-#### Inspection requested via web by Randy Fletcher 240.24(D)- Overcurrent devices shall not be located in the vicinity of easily ignitible material, such as clothes closets. 240.4- Max overcurrent for protection of conductors- 14 ga 15 amp max, 10 ga 30 amp max. 210.4(D)- Check multi-wire branch circuits for proper phasing to ensure grounded conductor does not carry current from both legs. *New wire dated 2013 in panel for furnace and master bath not on permit. 210.52- Receptacle outlet spacing in master bed and kitchen counter top areas does not comply with 210.52. *Record of 2 notices given to pull permits for remodel work, MIS14-00273, MIS14-00314.
|
ELE14-02834
| Final | 1/8/2015 | 1/9/2015 | 1/9/2015 8:33:53 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Laurie Hoelscher Sign listing confirmed. Final ok
|