Inspections for the day of: Tuesday, October 1, 2002.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC02-02771 Rough-in9/30/200210/1/200210/1/2002 12:00:00 AMAFAIL
rescheduled by 340 2 vent fan ducts not atched to fan box. 10/1/2002 11:14:06 AM
MEC02-02771 Pressure Test9/30/200210/1/200210/1/2002 12:00:00 AMAPASS
rescheduled by 340
BLD02-01514 BLD-Wall cover9/30/200210/1/200210/1/2002 12:00:00 AMAFAIL
1. FIRE BLOCKING - In combustible construction fire blocking shall be provided (1) In concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10-foot intervals both vertical and horizontal, (2) At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings, (3) In concealed spaces between stair stringers at the top and bottom of the run and between studs along and in line with the run of stairs if the walls under the stairs are unfinished, (4) In openings around vents, pipes, ducts, chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials, and (5) at openings between attic spaces and chimney chases for factory-built chimneys. (1997 UBC 708.2.1) Where fire blocks are allowed to be of combustible materials, fireblocking shall consist of 2 inches nominal lumber or two thicknesses of 1-inch nominal lumber with broken lap joints or one thickness of 23/32-inch wood structural panel with joints backed by 23/32-inch wood structural panel. Fire blocks may also be gypsum board, cement fiber board, batts or blankets of mineral or glass fiber, or other approved materials installed in such a manner as to be securely retained in place. (1997 UBC 708.2.2) at entry and ceilling of fire place.

2. provide insulation at garage wall at com. cable box to meet r-value as well as dryer duct.
BLD02-01760 BLD-Framing/Rough-in9/30/200210/1/200210/1/2002 12:00:00 AMAPART
martin; Phone #: ###-#### Internet Inspection Request from: Annette Moore framing ok pending plm sign off. 10/1/2002 10:01:05 AM
BLD02-01869 BLD-Energy code compliance9/30/200210/1/200210/1/2002 12:00:00 AMPPASS
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
BLD02-02215 BLD-Foundation10/1/200210/1/200210/1/2002 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 10/01/2002 at 07:11:49. Contact: ###-####.
BLD02-02108 BLD-Foundation10/1/200210/1/200210/1/2002 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 10/01/2002 at 07:35:50. Contact: ###-####.
MEC02-02782 Rough-in10/1/200210/1/200210/1/2002 12:00:00 AMPNR
Scheduled by a contractor via Hello! on 10/01/2002 at 08:46:09. Contact: ###-####.no valve on meter gas line work in progess in crawl. 10/1/2002 3:57:09 PM
BLD02-02251 BLD-Foundation10/1/200210/1/200210/1/2002 12:00:00 AMPPASS
found wall wes; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
BLD02-02256 BLD-Footing10/1/200210/1/200210/1/2002 12:00:00 AMPPASS
###-#### ft ok 10/1/2002 3:12:57 PM
BLD02-02037 BLD-Footing10/1/200210/1/200210/1/2002 12:00:00 AMPNR
JIM ###-####
BLD02-02013 BLD-Footing10/1/200210/1/200210/1/2002 12:00:00 AMPNR
JIM ###-####
BLD02-02038 BLD-Footing10/1/200210/1/200210/1/2002 12:00:00 AMPNR
JIM ###-####