MEC08-02586
| Final | 10/1/2008 | 10/1/2008 | 10/1/2008 2:57:05 PM | P | FAIL |
|
|
johnny Phone #: ###-#### fd installed incorrectly and need sediment trap before reg on horizontal piping at spray booth
|
MEC08-02768
| Final | 9/30/2008 | 10/1/2008 | 10/1/2008 1:27:16 PM | P | PASS |
|
|
EARLY PM IF POSSIBLE PLEASE Phone #: ###-#### Internet Inspection Request from: Donna Bledsoe
|
MEC08-02577
| Final | 9/30/2008 | 10/1/2008 | 10/1/2008 10:42:57 AM | A | PASS |
|
|
marty Note: please call 1/2 hr prior to inspection Phone #: ###-####
|
MEC08-02754
| Pressure Test | 9/30/2008 | 10/1/2008 | 10/1/2008 10:04:39 AM | A | PASS |
|
|
20#
|
MEC08-02754
| Rough-in | 10/1/2008 | 10/1/2008 | 10/1/2008 10:04:25 AM | A | FAIL |
|
|
remove gas flex connector from entering into furnace housing, need plumbing permit for w/h and run t&p to exterior, condensate drain shall be indirect waste to sewer system
|
MEC08-02749
| Rough-in | 9/30/2008 | 10/1/2008 | 10/1/2008 9:22:30 AM | A | PASS |
|
|
we should be good now. Internet Inspection Request from: Veronica Shipley no access to check furnace exhaust, need to check at final
|
MEC08-02751
| Rough-in | 9/30/2008 | 10/1/2008 | 10/1/2008 8:56:59 AM | A | PASS |
|
|
aaron Phone #: ###-####
|