Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-02037 Final10/1/201410/1/201410/1/2014 2:54:07 PMPNR
Phone #: ###-#### Inspection requested via web by Darryn Coburn painting, no access
ELE14-02452 Electrical Rough-In10/1/201410/1/201410/1/2014 2:53:04 PMPPASS
Need an ok to cover the underground raceways. Phone #: ###-#### Inspection requested via web by John Edwards ok cover u/g under slab
ELE14-01988 Electrical Rough-In10/1/201410/1/201410/1/2014 2:20:19 PMPPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton all but 12' ceilings ok cover
ELE14-02712 Electrical Rough-In9/30/201410/1/201410/1/2014 1:10:36 PMAPASS
Left side of house to back patio. Inspection requested via web by Terry Scott ri ok
ELE14-02715 Electrical Rough-In9/30/201410/1/201410/1/2014 12:40:48 PMAPASS
Bonding and Underground cover Phone #: ###-#### Inspection requested via web by Kevin Koomler pool bond and u/g ok cover
ELE14-02529 Final9/30/201410/1/201410/1/2014 11:35:57 AMAFAIL
Need ceiling inspection also. Call if you can''t get in I will give you the lockbox code Phone #: ###-#### Inspection requested via web by robert feller called, left correction notice, NEC 358.30(A) shall securely fasten emt within 3' of panel, 330.30(B) shall securely strap mc within 12" of termination, 210.8(B)(5) shall provide gfci outlet within 6' of sink, 408.4 circuit directory shall be clear, concise, and specific for it's purpose, 725.25 all class 2, 3 , pltc cables shall be removed if abandoned, 300.11(A) cables and raceways shall not be supported by ceiling grid, BCC no violations shall be retained
ELE14-02599 Final9/30/201410/1/201410/1/2014 11:02:08 AMAPASS
Ready for ceiling cover and final thank-you. Phone #: ###-#### Inspection requested via web by Kevin Oderkirk ok cover ceiling, ok final, signed card
ELE14-02355 Final9/30/201410/1/201410/1/2014 10:24:26 AMAPASS
Phone #: ###-#### Inspection requested via web by Celinda Winters ok final
ELE14-01719 Final9/30/201410/1/201410/1/2014 10:20:43 AMAPASS
Final for blanket Bob Phone #: ###-#### Inspection requested via web by Ken Heller ok final
ELE14-02713 Final9/30/201410/1/201410/1/2014 9:50:19 AMAPASS
Phone #: ###-#### Inspection requested via web by Bryan Atkins ok final
ELE14-02713 Permanent Service10/1/201410/1/201410/1/2014 9:50:09 AMAPASS
Phone #: ###-#### Inspection requested via web by Bryan Atkins p/s u/g rec ok
ELE14-02149 Final9/30/201410/1/201410/1/2014 9:15:57 AMAPASS
GARAGE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn ok final
ELE14-02058 Final9/30/201410/1/201410/1/2014 8:38:02 AMAPASS
Garage Code 1979E. Phone #: ###-#### Inspection requested via web by Alan Lusk ok final
ELE14-01900 Final9/30/201410/1/201410/1/2014 8:11:18 AMAPASS
GARAGE 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn ok final