Inspections for the day of: Wednesday, October 1, 2014.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-01395 Final10/1/201410/1/201410/1/2014 2:57:54 PMPPASS
Rex, Please call Dick at the listed phone number....he is available today to meet with you. He is working in Kuna this morning so if you can give him some heads up on a meeting time that would be great.
Thank you, Phone #: ###-#### Inspection requested via web by Rhonda Zamagni final ok
ELE13-01406 Final10/1/201410/1/201410/1/2014 2:23:49 PMPPASS
Daryl, Please call Dick at the listed phone number....he is available today to meet with you. He is working in Kuna this morning so if you can give him some heads up on a meeting time that would be great. I have requested both sites again so which ever may be easier to meet at would be great. He is meeting Rex today as well, that site is located near State St. and Dewey if that helps at all for coordinating schedules. Gate code 1256

Thank you, Phone #: ###-#### Inspection requested via web by Rhonda Zamagni final ok
ELE14-02696 Final10/1/201410/1/201410/1/2014 2:13:50 PMPNR
Mark Phone #: ###-#### Not ready final at this time
ELE14-02696 Conference10/1/201410/1/201410/1/2014 2:11:16 PMPDONE
Spoke with homeowner grounding and bonding for overhead 60 ampere moblehome servive.
ELE14-00902 Final10/1/201410/1/201410/1/2014 1:23:05 PMPFAIL
Please call so we can get you in.
Thanks
Eddy ###-#### Phone #: ###-#### Inspection requested via web by Eddy Udry NEC 406.8(B)(1) Front outside receptacles requires WR device.Washer receptaccle within 6ft. of sink require GFCI. Master bath vanity receptacle requires GFCI protection.Aluminum flex on A/C unit replace with LFNC.Install photo cell for garage lights
ELE14-02137 Final9/30/201410/1/201410/1/2014 12:32:58 PMAFAIL
Ryan Phone #: ###-#### NEC 210.8 (A)(7) All 15 and 20 ampere 120 volt receptacle within 6 ft. of an sink, basin require GFCI protection (kitchen) NEC406.4(D) Grounding type receptacle shall be connected to equipment grounding conductor.
ELE12-00213 Final9/30/201410/1/201410/1/2014 11:53:56 AMAPASS
Dan// as early as possible please Phone #: ###-#### correction done, final ok
ELE14-02678 Final9/30/201410/1/201410/1/2014 11:38:56 AMAPASS
Phone #: ###-#### Inspection requested via web by Don Conley correction done, final ok
ELE14-02717 Electrical Rough-In10/1/201410/1/201410/1/2014 11:25:22 AMAPASS
Underground inspection Phone #: ###-#### Inspection requested via web by Chris Chesnut rough-in ok cover service conduits from garage to house, foam seal under front patio
ELE14-01831 Final9/30/201410/1/201410/1/2014 10:45:58 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn final ok