ELE13-01395
| Final | 10/1/2014 | 10/1/2014 | 10/1/2014 2:57:54 PM | P | PASS |
|
|
Rex, Please call Dick at the listed phone number....he is available today to meet with you. He is working in Kuna this morning so if you can give him some heads up on a meeting time that would be great. Thank you, Phone #: ###-#### Inspection requested via web by Rhonda Zamagni final ok
|
ELE13-01406
| Final | 10/1/2014 | 10/1/2014 | 10/1/2014 2:23:49 PM | P | PASS |
|
|
Daryl, Please call Dick at the listed phone number....he is available today to meet with you. He is working in Kuna this morning so if you can give him some heads up on a meeting time that would be great. I have requested both sites again so which ever may be easier to meet at would be great. He is meeting Rex today as well, that site is located near State St. and Dewey if that helps at all for coordinating schedules. Gate code 1256
Thank you, Phone #: ###-#### Inspection requested via web by Rhonda Zamagni final ok
|
ELE14-02696
| Final | 10/1/2014 | 10/1/2014 | 10/1/2014 2:13:50 PM | P | NR |
|
|
Mark Phone #: ###-#### Not ready final at this time
|
ELE14-02696
| Conference | 10/1/2014 | 10/1/2014 | 10/1/2014 2:11:16 PM | P | DONE |
|
|
Spoke with homeowner grounding and bonding for overhead 60 ampere moblehome servive.
|
ELE14-00902
| Final | 10/1/2014 | 10/1/2014 | 10/1/2014 1:23:05 PM | P | FAIL |
|
|
Please call so we can get you in. Thanks Eddy ###-#### Phone #: ###-#### Inspection requested via web by Eddy Udry NEC 406.8(B)(1) Front outside receptacles requires WR device.Washer receptaccle within 6ft. of sink require GFCI. Master bath vanity receptacle requires GFCI protection.Aluminum flex on A/C unit replace with LFNC.Install photo cell for garage lights
|
ELE14-02137
| Final | 9/30/2014 | 10/1/2014 | 10/1/2014 12:32:58 PM | A | FAIL |
|
|
Ryan Phone #: ###-#### NEC 210.8 (A)(7) All 15 and 20 ampere 120 volt receptacle within 6 ft. of an sink, basin require GFCI protection (kitchen) NEC406.4(D) Grounding type receptacle shall be connected to equipment grounding conductor.
|
ELE12-00213
| Final | 9/30/2014 | 10/1/2014 | 10/1/2014 11:53:56 AM | A | PASS |
|
|
Dan// as early as possible please Phone #: ###-#### correction done, final ok
|
ELE14-02678
| Final | 9/30/2014 | 10/1/2014 | 10/1/2014 11:38:56 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Don Conley correction done, final ok
|
ELE14-02717
| Electrical Rough-In | 10/1/2014 | 10/1/2014 | 10/1/2014 11:25:22 AM | A | PASS |
|
|
Underground inspection Phone #: ###-#### Inspection requested via web by Chris Chesnut rough-in ok cover service conduits from garage to house, foam seal under front patio
|
ELE14-01831
| Final | 9/30/2014 | 10/1/2014 | 10/1/2014 10:45:58 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn final ok
|