MEC15-04608
| Final | 10/1/2015 | 10/1/2015 | 10/1/2015 4:35:43 PM | P | PASS |
|
|
Please call homeowner Vorene 30 mins prior to arrival ###-#### Phone #: ###-#### Inspection requested via web by James Staley
|
MEC15-04539
| Final | 9/28/2015 | 10/1/2015 | 10/1/2015 3:38:04 PM | P | PASS |
|
|
Please call Chad b4 arrival to arrange time and access Phone #: ###-#### Inspection requested via web by Diane Day
|
MEC15-04609
| Final | 10/1/2015 | 10/1/2015 | 10/1/2015 2:51:47 PM | P | PASS |
|
|
installer Cody ###-#### Phone #: ###-#### Inspection requested via web by Dustin Rich
|
MEC15-04609
| Pressure Test | 10/1/2015 | 10/1/2015 | 10/1/2015 2:51:01 PM | P | PASS |
|
|
p/t is for flue, installer Cody ###-#### Phone #: ###-#### Inspection requested via web by Dustin Rich - 5lb flue pass
|
MEC15-04551
| Conference | 9/30/2015 | 10/1/2015 | 10/1/2015 2:32:48 PM | P | NR |
|
|
Please call Random @ ###-#### prior to inspection Phone #: ###-#### Inspection requested via web by Tami Kelly
|
MEC14-02170
| Rough-in | 10/1/2015 | 10/1/2015 | 10/1/2015 2:24:38 PM | P | CANC |
|
|
Ben ###-####/D parking garage, residents storage , elevator lobby temp occupancy. Phone #: ###-#### Inspection requested via web by Crystal Grant - This was scheduled on the wrong permit.
|
MEC15-04529
| Rough-in | 10/1/2015 | 10/1/2015 | 10/1/2015 1:41:42 PM | P | PASS |
|
|
questions, Lupe was installer ###-####, sales is Dennis ###-#### Phone #: ###-#### Inspection requested via web by Dustin Rich
|
MEC15-04570
| Rough-in | 9/29/2015 | 10/1/2015 | 10/1/2015 10:49:11 AM | A | PASS |
|
|
Inspection requested via web by Don Dowers
|
MEC15-04570
| Pressure Test | 9/29/2015 | 10/1/2015 | 10/1/2015 10:48:50 AM | A | FAIL |
|
|
Inspection requested via web by Don Dowers - not holding pressure
|
MEC15-03659
| Final | 9/30/2015 | 10/1/2015 | 10/1/2015 10:27:16 AM | A | PASS |
|
|
Call technician Steve if there are any questions or concerns Phone #: ###-#### Inspection requested via web by Olivia Hicks
|
MEC15-04534
| Final | 9/28/2015 | 10/1/2015 | 10/1/2015 10:13:11 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brad Allison
|
MEC15-04595
| Pressure Test | 9/30/2015 | 10/1/2015 | 10/1/2015 10:10:16 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - 20lb gas, 5lb flue pass
|
MEC15-04595
| Rough-in | 9/30/2015 | 10/1/2015 | 10/1/2015 10:09:33 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - missing return transfer in master bedroom
|
MEC15-04606
| Rough-in | 9/30/2015 | 10/1/2015 | 10/1/2015 9:44:19 AM | A | PASS |
|
|
Please schedule inspection for AM, tomorrow (rough-in only). Please have inspector call 30 minutes ahead to Tom (Nephew): ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson
|
MEC15-04596
| Final | 9/30/2015 | 10/1/2015 | 10/1/2015 9:22:40 AM | A | PASS |
|
|
Please be mid morning the homeowners are elderly and need time to answer the door. Thanks Phone #: ###-#### Inspection requested via web by Allie Courter
|
MEC15-04444
| Final | 9/23/2015 | 10/1/2015 | 10/1/2015 8:57:42 AM | A | PASS |
|
|
###-#### homeowner-would like as early as possible-or call Kevin ###-####
|
MEC15-02703
| Final | 9/30/2015 | 10/1/2015 | 10/1/2015 8:35:06 AM | A | PASS |
|
|
Please call Roy at ###-#### with any questions or concerns. Thank you, Phone #: ###-#### Inspection requested via web by Taylor Nielsen
|
MEC14-02647
| Final | 10/1/2015 | 10/1/2015 | 10/1/2015 8:28:17 AM | A | PASS |
|
|
|
MEC15-03919
| Final | 9/29/2015 | 10/1/2015 | 10/1/2015 8:16:35 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Joe Bertwell
|
MEC14-00352
| Mec-Aging Inspection | 10/1/2015 | 10/1/2015 | 10/1/2015 6:59:15 AM | | CANC |
|
|
|
MEC14-00370
| Mec-Aging Inspection | 10/1/2015 | 10/1/2015 | 10/1/2015 6:58:19 AM | | CANC |
|
|
|
MEC14-04889
| Mec-Aging Inspection | 10/1/2015 | 10/1/2015 | 10/1/2015 6:57:44 AM | | CANC |
|
|
|