Inspections for the day of: Tuesday, October 1, 2019.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-03258 Permanent Service10/1/201910/1/201910/1/2019 2:06:15 PMPCANC
Pre-release inspection to allow power reconnect with utility. Phone #: ###-#### Inspection requested via web by BRS Permitting...cancelled by contractor...issues with service change
ELE17-03420 DOC - Permit Expired10/1/201910/1/201910/1/2019 2:02:02 PMPPASS
no visible sign...no activity over 180 days...permit expired
ELE19-01489 Electrical Rough-In9/30/201910/1/201910/1/2019 1:45:55 PMPPASS
Wall cover area C. Dave is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen...wall cover marked on contractors plans...adding corridor and media room
ELE17-00197 ELE-Aging Inspection10/1/201910/1/201910/1/2019 1:06:28 PM FAIL
contractor ignoring and making no attempt...has been made aware of...next action posting correction notice at job site
ELE19-03715 Electrical Rough-In10/1/201910/1/201910/1/2019 1:04:28 PMPPASS
Underground inspection Phone #: ###-#### Inspection requested via web by Kevin Perez...
underground for floor boxes ok to cover
ELE19-02807 Final9/30/201910/1/201910/1/2019 11:08:01 AMPCANC
Contact Mike Garcia for access ###-#### Phone #: ###-#### Inspection requested via web by Jeremy Cloud....building permit under review ...revised plans needed on jobsite for work verification
ELE19-02807 Conference10/1/201910/1/201910/1/2019 11:06:26 AMAPASS
Contact Matt for access ###-#### Phone #: ###-#### Inspection requested via web by Jeremy Cloud....discussed requirements for final inspection...grounding verification for new panels, labelling panels and devices, and GFCI protection in all areas
ELE19-02630 Permanent Service9/30/201910/1/201910/1/2019 10:42:28 AMAFAIL
Please call when you are in route. Phone #: ###-#### Inspection requested via web by Spencer McLean...
1)available fault current label needs applied before power can be given
2) 2nd ground rod needs verified for service...found only 1
ELE19-03258 Electrical Rough-In9/24/201910/1/201910/1/2019 10:05:30 AMPCANC
Pre-release inspection to allow power reconnect with utility. Phone #: ###-#### Inspection requested via web by BRS Permitting...needed perm service inspection for service change...permit fees needed corrected as well...service change needs added...journeyman informed
ELE19-03258 Electrical Rough-In10/1/201910/1/201910/1/2019 10:03:19 AMAPASS
Phone #: ###-#### Inspection requested via web by BRS Permitting...
UL listed equipment verified
ELE19-03494 Final10/1/201910/1/201910/1/2019 10:00:29 AMAPASS
Call with any questions Phone #: ###-#### Inspection requested via web by Garrett Collins...
ok to final
ELE18-02833 Final9/30/201910/1/201910/1/2019 9:06:40 AMAFAIL
mike Phone #: ###-####...no one home and no answer on contact phone given
ELE19-02645 Electrical Rough-In9/27/201910/1/201910/1/2019 8:31:39 AMAPASS
Please call 20 min prior for site access. Phone #: ###-#### Inspection requested via web by Derek Jackson...UL listed equipment...home owner does solar for living Aurora Solar
ELE17-03492 ELE-Aging Inspection10/1/201910/1/201910/1/2019 7:59:24 AM PASS
waiting on owner
ELE19-01489 Electrical Rough-In9/30/201910/1/20199/30/2019 9:26:12 AMACANC
Wall cover for Area C and Media room Phone #: ###-#### >> Inspection requested via web by Tyler Bowen Inspection cancelled from web by: Buster Bowen