Inspections for the day of: Tuesday, October 10, 2006.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-00821 ELE-Aging Inspection10/10/200610/10/200610/16/2006 9:01:23 AM PART
wsuc
ELE06-03662 Final10/10/200610/10/200610/10/2006 4:34:26 PMPCANC
Electrician: Allen; Phone #: ###-#### Internet Inspection Request from: Tawnya McKinney contr will call for r/i not final
ELE06-03730 Rough-In Permanent Service10/9/200610/10/200610/10/2006 4:14:19 PMPPASS
tom; Phone #: ###-#### Internet Inspection Request from: Patricia Smith r/i p/s u/g rec. ok
ELE06-03756 Electrical Rough-In10/10/200610/10/200610/10/2006 3:44:11 PMPFAIL
brandon; Phone #: ###-#### Internet Inspection Request from: Darla Downs
corr. met owner corr. note owner did not not call for conference before r/i 110.14(B) shall complete all makeup and use approved devices for splices wires just twisted, 210.52(A) needs outlets for 2ft walls entry to bedrm ,wall by door to closet, 300.4(A)(!)&(D) nail plates adn 11/4" parallel, 210.11(C)(3)&210.52(D) remove hall outlet from bath circuit, 300.14 needs 6" free length all location, explained everything to owner , owner just wanted to argue
ELE06-02501 Final10/10/200610/10/200610/10/2006 2:16:56 PMPFAIL
jermey; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
called needs 2 circuits to feed kit counter tops, no access to garage
ELE06-03701 Rough-In Permanent Service10/10/200610/10/200610/10/2006 2:02:12 PMPCANC
Scheduled by a contractor via Hello! on 10/10/2006 at 8:32:10 AM. Contact: ###-####. see added r/i
ELE06-03701 Electrical Rough-In10/10/200610/10/200610/10/2006 2:01:55 PMPPASS
Scheduled by a contractor via Hello! on 10/10/2006 at 8:32:10 AM. Contact: ###-####. house and concrete cover for electrode ok, jtub ok
ELE06-01236 Final10/10/200610/10/200610/10/2006 1:29:48 PMPFAIL
garage code is 6008. The key is on top of the furnace.; Phone #: ###-#### Internet Inspection Request from: steve creswell corrections not made more created, fee due called left message,408.4 shall be specific area type and purpose panel schedule, 410.14(B) needs access to box back of electric discharge fixture, remove wiring from other blanked off box in MB closet
ELE06-03759 Temporary Service10/10/200610/10/200610/10/2006 1:06:11 PMPFAIL
chad; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
corr. called 250.53 drive grd rod flush, 358.42 needs UL listed r/t fitting
ELE06-03761 Rough-In Permanent Service10/10/200610/10/200610/10/2006 12:42:15 PMPCANC
Please call so I can meet you there to show what is being done need meter for space and wall cover Thanks Don; Phone #: ###-#### Internet Inspection Request from: Don Lustig needs bld permit for tennat space?
ELE06-02881 Final10/9/200610/10/200610/10/2006 11:44:18 AMAFAIL
jack - note: please call 1/2 hr. prior ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith corr. 210.8(A)(2) needs gfci for recepts in work shop/hobby room, 408.4 circuit directory be specific area and purpose, 410.14(B) access to box above electric discharge fixtures?
ELE06-03296 Permanent Service10/9/200610/10/200610/10/2006 11:11:35 AMANR
Scheduled by a contractor via Hello! on 10/9/2006 at 1:43:04 PM. Contact: ###-####. grounding not complete, needs bushings for #4 and larger
ELE06-03296 Electrical Rough-In10/10/200610/10/200610/10/2006 11:10:19 AMAPART
Scheduled by a contractor via Hello! on 10/9/2006 at 1:43:04 PM. Contact: ###-####. electrode ok for concrete cover
ELE06-03745 Electrical Rough-In10/9/200610/10/200610/10/2006 11:09:33 AMAPASS
access number is ###-####. micheal thatcher. access will be available after 10 am thanks joe; Phone #: ###-#### Internet Inspection Request from: joe
wheeler r/i for kit remodel ok note desk is not in kit or din rm according to prints
ELE06-03709 Permanent Service10/9/200610/10/200610/9/2006 4:11:01 PMAPASS
Work performed by Kyle Sharp.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz p/s o/h rec. ok