Inspections for the day of: Monday, October 10, 2011.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02310 Rough-In Permanent Service10/10/201110/10/201110/10/2011 3:39:51 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by daniel bibikov protect cables attic access, outside boxes shall be flush with siding, outlet on wall in din.rm. shall be on SABC
ELE11-02255 Permanent Service10/10/201110/10/201110/10/2011 3:36:16 PMPPASS
John piatt Phone #: ###-#### p/s u/g rec ok
ELE11-02255 Final10/10/201110/10/201110/10/2011 3:36:00 PMPPASS
ELE11-01284 Electrical Rough-In10/10/201110/10/201110/10/2011 3:35:39 PMPFAIL
mike Phone #: ###-#### met owner, box fill, free length, 11/4", remove metal conn. from plastic boxes
ELE11-02273 Rough-In Permanent Service10/10/201110/10/201110/10/2011 3:34:10 PMPPASS
please call jeff ###-#### if any corrections. Thanks, Andrea. Phone #: ###-#### x0000 >> Inspection requested via web by Andrea Creek p/s u/g new ok
ESC11-00722 Site Preparation10/10/201110/10/201110/10/2011 3:33:48 PM NR
no work of any type has started
ELE11-02314 Permanent Service10/10/201110/10/201110/10/2011 12:27:56 PMPPASS
Inspection to have ID Power reconnect power. Please call Bob Bowman at ###-#### to confirm access to building. Call ###-#### with any questions. Thanks. Eric Phone #: ###-#### >> Inspection requested via web by Eric Schroeder p/s o/h rec. for meter ok
ELE11-02314 Final10/10/201110/10/201110/10/2011 12:27:27 PMPPASS
ELE11-01265 Final10/10/201110/10/201110/10/2011 11:48:50 AMPPASS
ELE11-00789 Final10/10/201110/10/201110/10/2011 11:48:27 AMPPASS
ELE11-01814 Final10/10/201110/10/201110/10/2011 11:48:01 AMPPASS
retro final
ELE11-00832 Electrical Rough-In10/7/201110/10/201110/10/2011 11:46:58 AMAFAIL
john please call 30 min before going out Phone #: ###-#### owner not doing work, correction posted, box fill boxes shall be flush with siding, needs switch and light outdoor exits, remove old wiring and breakers subjected too heat from fire, required clearence for panel , needs 2 grd rods, needs WR and TR recepts, needs backfed clip for main breaker remove or correct all wiring in violation of NEC, wiring too pump
ELE11-02282 Rough-In Permanent Service10/7/201110/10/201110/10/2011 11:40:55 AMAPASS
THANKS Phone #: ###-#### >> Inspection requested via web by Bob Glenn
p/s u/g new ok
ELE11-01586 Final10/7/201110/10/201110/10/2011 11:40:27 AMAPASS
Final (Gas pipe was moved as requested) Phone #: ###-#### >> Inspection requested via web by Brandon Winters