Inspections for the day of: Thursday, October 10, 2013.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-01195 ELE-Aging Inspection10/10/201310/10/201310/16/2013 3:29:14 PM DONE
Drove by and inspected
ELE12-00377 ELE-Aging Inspection10/10/201310/10/201310/16/2013 10:05:32 AM DONE
Still under construction
ELE13-01933 Temporary Service10/10/201310/10/201310/10/2013 4:58:01 PMPPASS
don''t know why this permit is still here Phone #: ###-#### >> Inspection requested via web by Darryn Coburn temp service gone, house built. Final ok on temp pole
ELE13-02796 Electrical Rough-In10/8/201310/10/201310/10/2013 4:37:31 PMPPASS
Phone #: ###-#### >> Inspection requested via web by PAT MILLER rough in ok
ELE13-02796 Final10/10/201310/10/201310/10/2013 4:33:47 PMPPASS
Phone #: ###-#### >> Inspection requested via web by PAT MILLER Final ok
ELE13-01378 Final10/9/201310/10/201310/10/2013 4:16:07 PMPPASS
Contact: Frank Yantis Phone #: ###-#### >> Inspection requested via web by Deb Gooden Final ok
ELE13-01377 Final10/9/201310/10/201310/10/2013 3:57:36 PMPPASS
Contact: Frank Yantis Phone #: ###-#### >> Inspection requested via web by Deb Gooden Final ok
ELE13-02734 Final10/10/201310/10/201310/10/2013 3:56:48 PMPPASS
Contact: Frank Yantis Phone #: ###-#### >> Inspection requested via web by Deb Gooden Final ok
ELE13-02740 Final10/10/201310/10/201310/10/2013 3:56:11 PMPPASS
Partial final for myer cabinet for perimeter poles Loads not complete, labelling. Partial final ok
ELE13-02735 Final10/10/201310/10/201310/10/2013 3:52:15 PMPPART
Partial final for myers cabinets for perimeter poles. ###-#### Loads not complete, labelling. Partial final ok
ELE13-01376 Final10/9/201310/10/201310/10/2013 3:45:11 PMPPART
Contact: Frank Yantis Phone #: ###-#### >> Inspection requested via web by Deb Gooden Service not energized. All accessible boxes closed. Partial final ok
ELE12-01710 Permanent Service10/10/201310/10/201310/10/2013 2:32:05 PMPPASS
Contact: Wes Powell Phone #: ###-#### >> Inspection requested via web by Deb Gooden Fire pump service p/s u/g n ok
ELE13-02830 Electrical Rough-In10/10/201310/10/201310/10/2013 2:20:58 PMPPASS
Contact: Wes Powell Phone #: ###-#### >> Inspection requested via web by Deb Gooden Baths 114, 115 wall and lids, rooms 116, 117 wall rough in ok cover
ELE13-01954 Final10/9/201310/10/201310/10/2013 1:30:27 PMAPASS
Phone #: ###-#### >> Inspection requested via web by Emmet Bushman House final ok
ELE13-02824 Rough-In Permanent Service10/10/201310/10/201310/10/2013 1:01:58 PMPPASS
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI Rough in ok cover p/s u/g n ok
ELE13-01663 Final10/9/201310/10/201310/10/2013 12:59:42 PMAPASS
Kevin-GFI for the tub is in the utility room under the cabinet; the furnace has a breaker lock out Phone #: ###-#### Final ok
GCE13-00163 GCE-Temporary Service10/9/201310/10/201310/10/2013 12:16:21 PMAFAIL
Daniel ###-#### This is start service inspection Single pole GFCI breaker missing.
Dead front of panel not secured, screw holes stripped out.
Multiple wires terminated in lugs not listed for more than 1.
ELE13-02816 Final10/9/201310/10/201310/10/2013 10:27:53 AMAPASS
Wee added 7 layin fixtures with dual switching Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot Final ok
ELE13-02816 Electrical Rough-In10/10/201310/10/201310/10/2013 10:26:40 AMPPASS
Wee added 7 layin fixtures with dual switching Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot Rough in ok cover
ELE13-02793 Rough-In Permanent Service10/10/201310/10/201310/10/2013 9:39:16 AMAPASS
If you could call me in advance so I can bring my ladder that would be great. Thanks Phone #: ###-#### >> Inspection requested via web by Neal Rumsey Rough in ok cover p/s u/g n ok
ELE13-02818 Electrical Rough-In10/9/201310/10/201310/10/2013 9:14:15 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Matthew Dunay Conduit and ground for solar rough in ok cover
ELE13-01376 Permanent Service10/9/201310/10/201310/10/2013 8:48:52 AMAPASS
Contact: Frank Yantis Phone #: ###-#### >> Inspection requested via web by Deb Gooden p/s u/g n ok
GCE13-00162 GCE-Rough-In10/9/201310/10/201310/10/2013 8:22:05 AMAPASS
Jim ###-#### Rough in ok cover p/s u/g n ok 2 meters required