Inspections for the day of: Tuesday, October 10, 2017.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-01134 Electrical Rough-In10/10/201710/10/201710/10/2017 3:48:52 PMPPART
We are requesting a final inspection for the patio for this afternoon. Our contact is Nic @ ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Clint Tate
Holiday receptacles GFCI protection shall be located in a readily accessible location as per 210.8. Fountain on patio not complete, shall verify GFCI protection.
TCO patio and pool 3rd level ok
ELE17-02862 Electrical Rough-In10/10/201710/10/201710/10/2017 2:56:34 PMPPASS
Ground work and east wall Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
Lower level underground and east wall rough in ok cover
ELE16-01483 Electrical Rough-In10/10/201710/10/201710/10/2017 2:26:20 PMPPASS
We need an fire alarm inspection for the electrical part of the fire alarm. On site Contact is Greg. Phone #: ###-#### Inspection requested via web by Stacie Tasker
Area noted rough in ok
ELE17-03385 Conference10/10/201710/10/201710/10/2017 1:54:03 PMPDONE
Please call ahead for access, in & out this afternoon - Richard Phone #: ###-#### Discussed the type of breakers listed for a square D homeline 816 all in one. Owner was told this is not able to accept a twin breaker. Verified on panel cover and by type of buss twins are ok in this panel. Also hard pipe to heater with flex to not transfer vibrations to wall.
ELE16-03931 Electrical Rough-In10/10/201710/10/201710/10/2017 11:10:52 AMAPASS
dropped lids in units 301, 302, 304, 306, 308, 310, 312, 314, 316, 318, 320, 322. corridors 3rd floor Phone #: ###-#### Inspection requested via web by Cathy Duchek
Areas noted hardlids rough in ok cover
ELE17-01653 Final10/9/201710/10/201710/10/2017 10:20:17 AMAPASS
Pan Channel letters were installed prior to new rules. This site is
ready for final inspection. Call Aaron with any questions Phone #: ###-#### Inspection requested via web by Dana Vance
Final ok
ELE17-01653 Electrical Rough-In10/10/201710/10/201710/10/2017 10:20:10 AMPPASS
Pan Channel letters were installed prior to new rules. This site is
ready for final inspection. Call Aaron with any questions Phone #: ###-#### Inspection requested via web by Dana Vance
Listing and disconnecting means confirmed. Rough in ok
ELE17-03398 Conference10/9/201710/10/201710/10/2017 9:57:26 AMADONE
Would like to meet inspector on site, please call with ETA ###-####.
Thank you. Phone #: ###-#### Inspection requested via web by David Nelson
Discussed required wiring of fire damaged appartments. All wiring damaged by heat or water shall be replaced as needed. Where units have totally opened up walls and ceilings, wiring shall be replaced to all new codes. Areas with only smoke damage not required to be brought up to code due to wiring not being replaced.
BCC 4-05-32 Code violations not to be retained. City ordinance requires code violations to be repaired even if damage is not present. Found paddle fans installed on boxes not rated for fans and microwaves installed on general lighting circuits with splice buried in walls. If fans to remain listed boxes shall be installed. Circuits shall be added for microwaves or hoods shall be istalled to eliminate overloads. If additional life safety code violations are found during rebuild they shall be repaired.
ELE17-03261 Temporary Service10/9/201710/10/201710/10/2017 8:32:36 AMAPASS
Phone #: ###-#### Inspection requested via web by Tracy Robertson
t/s u/g n ok
ELE17-03260 Temporary Service10/9/201710/10/201710/10/2017 8:32:03 AMAPASS
Phone #: ###-#### Inspection requested via web by Tracy Robertson
t/s u/g n ok
ELE17-03259 Temporary Service10/9/201710/10/201710/10/2017 8:31:40 AMAPASS
Phone #: ###-#### Inspection requested via web by Tracy Robertson
t/s u/g n ok
ELE17-03349 Rough-In Permanent Service10/9/201710/10/201710/10/2017 8:13:15 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn
Rough in ok cover p/s u/g n ok