Inspections for the day of: Wednesday, October 11, 2006.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-00043 Final10/11/200610/11/200610/11/2006 4:26:30 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Todd Holbrook
ELE06-00110 Final10/11/200610/11/200610/11/2006 3:44:10 PMPPASS
ryan; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
ELE06-03756 Electrical Rough-In10/11/200610/11/200610/11/2006 3:21:08 PMPPASS
brandon -re-insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
ELE06-03392 Permanent Service10/11/200610/11/200610/11/2006 2:41:02 PMPPASS
shawn; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
P/S O/H R Ok
ELE06-03781 Electrical Rough-In10/11/200610/11/200610/11/2006 1:54:48 PMPPASS
Tim; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
passed with survey for metal box bonding and handy box for back recep not big enough.
I cannot get info on job.
ELE06-03768 Electrical Rough-In10/10/200610/11/200610/11/2006 10:39:19 AMAPART
###-#### chris
floor ok
ELE06-03392 Final10/11/200610/11/200610/11/2006 10:27:36 AMPCANC
Phone #: ###-#### Internet Inspection Request from: Shaun Kirkman Inspection cancelled from web by: Patricia Smith
ELE06-03771 Permanent Service10/10/200610/11/200610/11/2006 9:52:13 AMAFAIL
JAMIE; Phone #: ###-#### Internet Inspection Request from: Darla Downs
electrod comes up outside the stem wall
no guy kit on riser and improper use of male adaptor with romex comming out of panel
ELE06-03749 Rough-In Permanent Service10/10/200610/11/200610/11/2006 9:35:39 AMAFAIL
ted; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
338.24 bending radius for cable
250.50 connect old water service to electrode system
install concrete encased electrode
250.24 connect electrode system to system grounded conductor
250.28 install main bonding jumper
2 in. is required for mast as support.
ELE06-03749 Electrical Rough-In10/11/200610/11/200610/11/2006 9:09:52 AMPPASS
ted; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
ELE06-03710 ELE-Request for Extension10/11/200610/11/200610/11/2006 8:30:02 AMACANC
Ted; Phone #: ###-#### Internet Inspection Request from: Shawna Hall
ELE06-03710 Electrical Rough-In10/11/200610/11/200610/11/2006 8:29:45 AMAPASS
Ted; Phone #: ###-#### Internet Inspection Request from: Shawna Hall
R/I Ok except sub panel wall