Inspections for the day of: Wednesday, October 11, 2017.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-01429 ELE-Aging Inspection10/11/201710/11/201710/12/2017 3:39:11 PM FAIL
Still waiting on contractor
ELE17-03393 Electrical Rough-In10/11/201710/11/201710/11/2017 2:25:43 PMPNR
Contact: Scot Grill - underground inspection please Phone #: ###-#### Inspection requested via web by Deb Gooden
Contact called, they got a late start, will recall when ready.
ELE17-03403 Temporary Service10/11/201710/11/201710/11/2017 2:11:55 PMPPASS
Service inspection
EOD preferred.
Contact Steve Hess
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek
t/s o/h n ok
ELE16-01483 Electrical Rough-In10/10/201710/11/201710/11/2017 1:46:54 PMAPASS
We need a ceiling cover for the entire 3rd floor. Phone #: ###-#### Inspection requested via web by Stacie Tasker
Area noted grid rough in ok cover
ELE17-03433 Electrical Rough-In10/10/201710/11/201710/11/2017 1:45:34 PMAFAIL
Garage door can be lifted for entry Phone #: ###-#### Inspection requested via web by Tyler Ridley
AFCI protection required for bedroom areas
210.52- Down bed 30" wall shall have receptacle outlet installed for wall space.
300.4- Where NM cable is run thru bored or notched studs that do not maintain 1 1/4" from framing surface they shall be protected from damage by nail plates. Master closet, master bath, end of hall.
300.15- All NM cable shall terminate in a box. Fireplace wiring.
300.15(A)(1)- All terminations shall be accessible. Smoke in basement hall not secured and sitting on duct.
334.12- NM cable shall not be installed where subject to damage. Up west bed upper hole will be partially cavered by drywall.
334.30- NM cable shall be supported at intervals not to exceed 4 1/2'. 14-3 for smokes from basement to up bed.
408.41- Grounded conductors shall terminate individually. Contractor called to clearify the termination of grounded and left prior to my return call. Told he could take care of this item by final would be OK
ELE17-01337 Electrical Rough-In10/10/201710/11/201710/11/2017 12:43:51 PMAPASS
We are requesting ceiling and wall rough-in inspections on the first floor for tomorrow morning. Our contact is Rick @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate
Managers work area, laundry, east of laundry to stair fire lids and 1 side construction office for heat lonly rough in ok cover
ELE17-01304 Final10/10/201710/11/201710/11/2017 10:57:04 AMAFAIL
please call 30 mins before- Joe Phone #: ###-####
314.20- installations in walls with wood or other combustible materials boxes shall be flush or extension rings shall be added.
406.12- All receptacle outlets installed in a residential garage shall be tamper resistant type if located below 5'5".
ELE14-00730 Final10/10/201710/11/201710/11/2017 8:44:39 AMAPASS
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle
Final ok
ELE14-00730 Electrical Rough-In10/11/201710/11/201710/11/2017 8:44:18 AMPPASS
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle
Listing and disconnecting means confirmed. Rough in ok
ELE17-02307 Electrical Rough-In10/10/201710/11/201710/11/2017 8:17:35 AMPCANC
Kitchen ri. As late as possible please. Phone #: ###-#### >> Inspection requested via web by Garrett Collins Inspection cancelled from web by: Garrett Collins