Inspections for the day of: Thursday, October 11, 2018.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-02405 ELE-Aging Inspection10/11/201810/11/201810/18/2018 8:12:01 AM FAIL
No attempt to final. Unable to leave message
ELE12-02469 ELE-Aging Inspection10/11/201810/11/201810/18/2018 8:00:06 AM FAIL
Still no respone or attempt to final
ELE18-03636 Final10/10/201810/11/201810/11/2018 2:49:15 PMPPASS
Jeff is the site contact. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker Final ok
ELE18-03823 Temporary Service10/11/201810/11/201810/11/2018 2:16:42 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
ELE18-02378 Final10/11/201810/11/201810/11/2018 1:07:25 PMPFAIL
Justin ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg 3 quad receps on N wall dead 210.8 all receps in an unfinished basement shall be GFCI protected Re-call when fixed
ELE18-01558 Final10/10/201810/11/201810/11/2018 12:11:13 PMAFAIL
second floor final Phone #: ###-#### Inspection requested via web by steve cooper No answer at number and unable to leave message. Panel blanks needed in rm.222. Exit sign next to stairs does not work. (Boxes shall be accessable as per 314.29 Rm 212 Recep at end of kitchen counter)
ELE18-03878 Rough-In Permanent Service10/11/201810/11/201810/11/2018 11:26:35 AMAPASS
Phone #: ###-#### Inspection requested via web by William Andrews rough in ok p/s u/g n ok
ELE18-03852 Temporary Service10/11/201810/11/201810/11/2018 10:58:05 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
ELE18-03728 Final10/10/201810/11/201810/11/2018 10:56:31 AMAPASS
Backyard - The gate by the meter will be unlocked, as well as the garage man door (panel).
* I will not be there.

Inspect the sub-panel, hot tub hook-up, and water feature outlet.

Thank you,
Lonnie Phone #: ###-#### Inspection requested via web by Lonnie Sorichta final ok
ELE18-02930 Final10/10/201810/11/201810/11/2018 9:56:21 AMAPASS
Garage code 1957E Phone #: ###-#### Inspection requested via web by Alan Lusk Corrections made final ok
ELE18-03831 Temporary Service10/10/201810/11/201810/11/2018 9:07:13 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
ELE18-03205 Final10/10/201810/11/201810/11/2018 8:57:58 AMAFAIL
key is behind the shop under rock Phone #: ###-#### Inspection requested via web by Kevin Heideman 210.8 All kitchen receps shall be gfci protected( East wall) 110.3 Equipment shall be installed as per man. specs.( Kitchen gfci west wall open grnd. Replaced receps in house Rev polarity. Dead recep East wall living room.)