ELE19-03907
| Final | 10/10/2019 | 10/11/2019 | 10/11/2019 3:14:03 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Needed conferene
|
ELE19-03907
| Conference | 10/11/2019 | 10/11/2019 | 10/11/2019 3:13:23 PM | P | DONE |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Discussed wiring done by others and service change, EC know if he takes job on they will be responsible for all done
|
ELE19-03429
| Final | 10/10/2019 | 10/11/2019 | 10/11/2019 3:08:45 PM | P | PASS |
|
|
I''ll be done by noon. Phone #: ###-#### Inspection requested via web by Andy Derrick Final ok
|
ELE19-01531
| Final | 10/11/2019 | 10/11/2019 | 10/11/2019 1:14:38 PM | P | FAIL |
|
|
Lock box code 4570. If you have any questions please feel free to contact Andrew ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan 210.8 Recetpacles located within 6' of a sink shall be GFCI protected 110.25 Lockabe Disc for hard wired appliances 410.16(b) pendants in a close closet with open lampholders shall not be permitted
|
ELE19-01628
| Electrical Rough-In | 10/10/2019 | 10/11/2019 | 10/11/2019 12:55:27 PM | A | PASS |
|
|
4th floor units for rough-in 4th floor units ok to cover
|
ELE19-02934
| Final | 10/10/2019 | 10/11/2019 | 10/11/2019 11:01:00 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Keith Chetta 210.8 All 120V recetpacles located within a bathroom shall have GFCI protection 210.70 (a)(2) (2) Dwellings units shall have a switch for egress for all exterior exits 110.25 Lockable Disc for all hard wired appliances
|
ELE19-02661
| Final | 10/11/2019 | 10/11/2019 | 10/11/2019 10:37:18 AM | A | PASS |
|
|
lock box code 9165 Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
|
ELE19-02659
| Final | 10/11/2019 | 10/11/2019 | 10/11/2019 10:36:29 AM | A | PASS |
|
|
lock box code 9165 Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
|
ELE19-02660
| Final | 10/11/2019 | 10/11/2019 | 10/11/2019 10:36:12 AM | A | PASS |
|
|
lock box code 9165 Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
|
ELE19-03750
| Final | 10/10/2019 | 10/11/2019 | 10/11/2019 9:59:51 AM | A | PASS |
|
|
It is all outside. There will be someone home. If you have any questions please feel free to contact Tony ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Service change and hot tub install ok
|
ELE19-03633
| Electrical Rough-In | 10/10/2019 | 10/11/2019 | 10/11/2019 9:43:38 AM | A | PASS |
|
|
This is for a cover inspection for the offices in the building. Any questions please call Darin Winters ###-#### Phone #: ###-#### Inspection requested via web by Sherry Allen Offices and bath walls and hard lids ok to cover(fans not installed at this point)
|