Inspections for the day of: Friday, October 12, 2001.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMarv Burrus
TitleELE
Phone #340-1297
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE01-02359 ELE-Aging Inspection10/12/200110/12/200110/12/2001 12:00:00 AM NR
no further inspections requested. 10/12/2001 9:01:20 AM
ELE01-01195 ELE-Aging Inspection10/12/200110/12/200110/12/2001 12:00:00 AM NR
no inspections requested. 10/12/2001 8:59:40 AM
ELE01-03277 Temporary Service10/11/200110/12/200110/12/2001 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 10/11/2001 at 11:36:54. Contact: ###-####. temporary pole

t/s ug tablerock construction #3277-ok. 10/12/2001 9:48:03 AM
ELE99-04339 Final10/11/200110/12/200110/12/2001 12:00:00 AMAFAIL
monica ###-#### fn--call 1st before insp. nec: 210-8. bathrooms shall have gfci protection for recepticle outlets. nec: 210-52. kitchen island cupboards shall have at least one gfci receptile outlet. 410-8. closet incandescant light fixture shall be at least 12 inches clearance or width of shelf which ever is greater, 10/12/2001 11:46:48 AM
ELE00-01560 Electrical Rough-In10/11/200110/12/200110/12/2001 12:00:00 AMAPART
###-#### JOSH. 5th floor eastend courtroom; raised floor r/i. 10/12/2001 9:02:03 AM
ELE01-03526 Electrical Rough-In10/11/200110/12/200110/12/2001 12:00:00 AMAPART
for lower pool on bonding insp kathy ###-####
ELE01-01532 Electrical Rough-In10/11/200110/12/200110/12/2001 12:00:00 AMAPASS
r/i- james -###-#### ext 235--call 1st before insp . front walls r/i ok. 10/12/2001 10:13:43 AM
ELE01-03502 Rough-In Permanent Service10/11/200110/12/200110/12/2001 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 10/11/2001 at 17:56:42. Contact: ###-####. ele r/i; perm/svc.

p/s ug n boise basin ele #3502-ok. 10/12/2001 12:19:54 PM
ELE01-02582 Final10/11/200110/12/200110/12/2001 12:00:00 AMPNH
pat f ###-####. no access; called contractor to reschedule. 10/12/2001 2:49:13 PM
ELE01-03533 Rough-In Permanent Service10/12/200110/12/200110/12/2001 12:00:00 AMPPART
partial on the r\i and complete service\###-####. shear-walls front and rear;
30 unit apartment complex ele r/i; perm/svc.

p/s ug n capitol ele #3533-ok
30 apartment complex, garage level. 10/12/2001 2:30:10 PM
ELE01-03535 Electrical Rough-In10/12/200110/12/200110/12/2001 12:00:00 AMPPART
###-#### MARK VOICE PAGER. 10th floor: physical theropy room walls r/i. 10/12/2001 3:25:13 PM